HP P2000 HP P2000 G3 MSA System Event Description Reference Guide - Page 19
Info., Recommended actions, Resources for diagnosing and, resolving problems
View all HP P2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
177 Info. Cache data was purged for the indicated missing volume. Recommended actions • No action required. 181 Info. Controller network port parameters have been changed. Recommended actions • No action required. 182 Info. All disk channels have been paused. I/O will not be performed on the disks until all channels are unpaused. Recommended actions • If this event occurs in relation to disk firmware update, no action is required. When the condition is cleared, event 183 is logged. • If this event occurs and you are not performing disk firmware update, see Resources for diagnosing and resolving problems on page 3. 183 Info. All disk channels have been unpaused, meaning that I/O can resume. An unpause initiates a rescan, which when complete is logged as event 19. This event indicates that a problem reported by event 182 is resolved. Recommended actions • No action required. 185 Info. An enclosure management processor (EMP) write command has completed. Recommended actions • No action required. 186 Info. Enclosure parameters have been changed by a user. Recommended actions • No action required. 187 Info. The write-back cache has been enabled. Recommended actions • Look for event 188. 188 Info. Write-back cache has been disabled. Recommended actions • If event 187 is not logged within a reasonable amount of time, see Resources for diagnosing and resolving problems on page 3. HP P2000 G3 MSA System Event Descriptions Reference Guide 19