HP P2000 HP P2000 G3 MSA System Event Description Reference Guide - Page 8
Info., Recommended actions, Error, Warning, Table 1 - disk firmware
View all HP P2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
47 Info. An error detected by the sensors has been cleared. This event indicates that a problem reported by event 39 or 40 is resolved. Recommended actions • No action required. 48 Info. The indicated vdisk has been renamed. Recommended actions • No action required. 49 Info. A lengthy SCSI maintenance command has completed. Output indicates whether it completed successfully or a failure occurred. (Typically appears after disk firmware update.) Recommended actions • No action required. 50 Info. A correctable ECC error occurred in buffer memory. Recommended actions • No action required. 51 Error An uncorrectable ECC error occurred in buffer memory. Recommended actions • If this event occurs only once, no action is required. • If the event occurs more than once, replace the controller reporting the event. 52 Info. Vdisk expansion has started. Recommended actions • This operation can take days to complete. When complete, event 53 is logged. 53 Info. Vdisk expansion either completed, failed, or was aborted by a user. Recommended actions • If the expansion failed because of a disk problem: replace the disk; if vdisk reconstruction starts, wait for it to complete; and then retry the expansion. 55 Warning A SMART event occurred on the indicated disk, indicating impending disk failure. Recommended actions • See Table 1 on page 42. 56 Info. A controller has powered up or restarted. Recommended actions • No action required. 8