HP P2000 HP P2000 G3 MSA System Event Description Reference Guide - Page 26

Info., Recommended actions, Warning - review

Page 26 highlights

243 Info. A new controller enclosure has been detected. This happens when a controller FRU is moved from one enclosure to another and the controller detects that the midplane WWN is different from the WWN it has in its local flash. Recommended actions • No action required. 245 Info. An existing disk channel target device is not responding to SCSI discovery commands. Recommended actions • Check the indicated target device for bad hardware or bad cable, then initiate a rescan. 246 Warning The coin battery is not present or is not properly seated or has reached end-of-life. The battery provides backup power for the real-time (date/time) clock. In the event of a power failure, the date and time will revert to January 1, 1970 00:00:00. Recommended actions • Replace the controller module reporting the event. 247 Warning The FRU ID SEEPROM for the indicated field replaceable unit (FRU) cannot be read; FRU ID data might not be programmed. FRU ID data includes the worldwide name, SCSI ID, and branding information. This event is logged once each time a Storage Controller is started for each FRU that is not programmed, and is logged by each I/O module. Recommended actions • Return the FRU to have its FRU ID data reprogrammed. 248 Info. A valid feature license was successfully installed. See event 249 for details about each licensed feature. Recommended actions • No action required. 249 Info. After a valid license is installed, this event is logged for each licensed feature to show the new license value for that feature. The event specifies whether the feature is licensed, whether the license is temporary, and whether the temporary license is expired. Recommended actions • No action required. 250 Warning A license could not be installed. The license is invalid or specifies an unsupported feature. Recommended actions • Review the readme file that came with the license. Verify that you are trying to install the license on the system that the license was generated for. 251 Warning A volume-copy operation has started for the indicated source volume. Recommended actions • If the source volume is a master volume, you can remount it. If the source volume is a snapshot, do not remount it until the copy is complete (as indicated by event 268). 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

26
243
Info.
A new controller enclosure has been detected. This happens when a controller FRU is moved from one
enclosure to another and the controller detects that the midplane WWN is different from the WWN it has
in its local flash.
Recommended actions
No action required.
245
Info.
An existing disk channel target device is not responding to SCSI discovery commands.
Recommended actions
Check the indicated target device for bad hardware or bad cable, then initiate a rescan.
246
Warning
The coin battery is not present or is not properly seated or has reached end-of-life. The battery provides
backup power for the real-time (date/time) clock. In the event of a power failure, the date and time will
revert to January 1, 1970 00:00:00.
Recommended actions
Replace the controller module reporting the event.
247
Warning
The FRU ID SEEPROM for the indicated field replaceable unit (FRU) cannot be read; FRU ID data might not
be programmed. FRU ID data includes the worldwide name, SCSI ID, and branding information. This event
is logged once each time a Storage Controller is started for each FRU that is not programmed, and is
logged by each I/O module.
Recommended actions
Return the FRU to have its FRU ID data reprogrammed.
248
Info.
A valid feature license was successfully installed. See event 249 for details about each licensed feature.
Recommended actions
No action required.
249
Info.
After a valid license is installed, this event is logged for each licensed feature to show the new license
value for that feature. The event specifies whether the feature is licensed, whether the license is temporary,
and whether the temporary license is expired.
Recommended actions
No action required.
250
Warning
A license could not be installed. The license is invalid or specifies an unsupported feature.
Recommended actions
Review the readme file that came with the license. Verify that you are trying to install the license on the
system that the license was generated for.
251
Warning
A volume-copy operation has started for the indicated source volume.
Recommended actions
If the source volume is a master volume, you can remount it. If the source volume is a snapshot, do not
remount it until the copy is complete (as indicated by event 268).