HP PageWide XL Pro 8200 User Guide - Page 233

Replace the folder’s tab reel, If calibration fails

Page 233 highlights

1. Clean the scanner. See Clean the scanner's glass plate on page 222. 2. Go to the front panel and tap , then Scanner preferences > Calibrate scanner. 3. Follow the instructions in the front panel. If calibration fails The following steps provide the complete procedure for this topic. The supplied maintenance sheet required to perform scanner calibration looks like this: Load the maintenance sheet into the scanner face up, centered and with as little skew as possible. Once the calibration is finished, the maintenance sheet should be carefully placed into its solid cover, and saved in a fresh and dry place. Otherwise, it could be damaged, which could affect the operation of your scanner in the future. Check that the maintenance sheet is not dirty, wrinkled, scratched or folded before calibrating the scanner. If necessary, call your service representative and ask for a new maintenance sheet. 1. Ensure that the printer is turned on and ready for normal operation. 2. Ensure that the scanner is working correctly. To test it, scan a small document to file. 3. Ensure that the scanner is clean before calibration. If in doubt, clean the scanner and restart the calibration process. 4. Eject and reload the calibration sheet, checking that it is clean, in good condition, face up and perfectly centered in the scanner. 5. If the above steps do not help, eject the sheet and restart the printer (turn off and on). When the system has restarted, repeat the calibration. 6. If you cannot perform the calibration successfully in three consecutive attempts, call your service representative and report the error code that appears in the front panel. Replace the folder's tab reel Follow these steps if you need to replace your folder's tab reel. If calibration fails 227

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260

1.
Clean the scanner. See
Clean the scanner’s glass plate on page 222
.
2.
Go to the front panel and tap
, then
Scanner preferences
>
Calibrate scanner
.
3.
Follow the instructions in the front panel.
If calibration fails
The following steps provide the complete procedure for this topic.
The supplied maintenance sheet required to perform scanner calibration looks like this:
Load the maintenance sheet into the scanner face up, centered and with as little skew as possible. Once the
calibration is finished, the maintenance sheet should be carefully placed into its solid cover, and saved in a fresh
and dry place. Otherwise, it could be damaged, which could affect the operation of your scanner in the future.
Check that the maintenance sheet is not dirty, wrinkled, scratched or folded before calibrating the scanner. If
necessary, call your service representative and ask for a new maintenance sheet.
1.
Ensure that the printer is turned on and ready for normal operation.
2.
Ensure that the scanner is working correctly. To test it, scan a small document to file.
3.
Ensure that the scanner is clean before calibration. If in doubt, clean the scanner and restart the calibration
process.
4.
Eject and reload the calibration sheet, checking that it is clean, in good condition, face up and perfectly
centered in the scanner.
5.
If the above steps do not help, eject the sheet and restart the printer (turn off and on). When the system has
restarted, repeat the calibration.
6.
If you cannot perform the calibration successfully in three consecutive attempts, call your service
representative and report the error code that appears in the front panel.
Replace the folder’s tab reel
Follow these steps if you need to replace your folder’s tab reel.
If calibration fails