HP ProLiant BL495c HP BladeSystem c-Class SAN connectivity technology brief - Page 11

FC SAN connectivity, Table 1.

Page 11 highlights

FC SAN connectivity Figure 8 shows FC port connectivity in the c7000 enclosure for full-height and half-height server blades connecting to a SAN through FC interconnect modules. Figure 8. Server blade-to-SAN connectivity for the HP c7000 Enclosure, dimensional view FC interconnect module in even-numbered bay SAN FC HBA mezzanine card (1x card) FC interconnect module in odd-numbered-bay Full-height server blade Port 1 routing Port 2 routing Half-height server blade c7000 enclosure midplane Each FC interconnect module (pass-thru, virtual connect, or switch) provides connections for up to 16 server blades. To ensure high availability, each FC HBA mezzanine card is dual-ported, and each port is routed to a separate interconnect bay. For example, as indicated in Figure 6 and in Table 1, the ports on an HBA mezzanine card in slot 1 are routed to bays 3 and 4. Interconnect modules must be installed in pairs if redundancy is required. Table 1. c-Class server blade mezzanine slot-to-interconnect bay port routing for FC HBA (1x port type) mezzanine cards Server blade mezzanine slot Slot 1: Port 1 Port 2 Slot 2: Port 1 Port 2 Slot 3: Port 1 Port 2 C7000 Interconnect bay 3 4 5 6 7 8 C3000 Interconnect bay 2 2 3 4 3 4 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

FC SAN connectivity
Figure 8 shows FC port connectivity in the c7000 enclosure for full-height and half-height server
blades connecting to a SAN through FC interconnect modules.
Figure 8
. Server blade-to-SAN connectivity for the HP c7000 Enclosure, dimensional view
SAN
c7000
enclosure
midplane
Half-height
server blade
FC HBA
mezzanine card
(1x card)
FC interconnect
module in
odd-numbered-bay
FC interconnect module
in even-numbered bay
Port 1 routing
Port 2 routing
Full-height
server blade
Each FC interconnect module (pass-thru, virtual connect, or switch) provides connections for up to 16
server blades. To ensure high availability, each FC HBA mezzanine card is dual-ported, and each
port is routed to a separate interconnect bay. For example, as indicated in Figure 6 and in Table 1,
the ports on an HBA mezzanine card in slot 1 are routed to bays 3 and 4. Interconnect modules must
be installed in pairs if redundancy is required.
Table 1.
c-Class server blade mezzanine slot-to-interconnect bay port routing for FC HBA (1x port
type) mezzanine cards
Server blade
mezzanine slot
C7000
Interconnect bay
C3000
Interconnect bay
Slot 1:
Port 1
Port 2
3
4
2
2
Slot 2:
Port 1
Port 2
5
6
3
4
Slot 3:
Port 1
Port 2
7
8
3
4