HP ProSignia 500 Compaq ProSignia Family of PC Servers Maintenance and Service - Page 31
Table 3-3. Memory Test Error Codes, Recommended Action
![]() |
View all HP ProSignia 500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
master test failed 105-xx Port 61 error 106-xx Keyboard controller self-test failed 107-xx CMOS RAM test failed The following steps apply to error codes 107-xx through 109-xx. 108-xx CMOS interrupt test 1. Replace the battery/clock module failed and retest. 2. Replace the system board and 109-xx CMOS clock load data test retest. failed 110-xx Programmable timer load Replace the system board and retest data test failed for error codes 110-xx through 113-xx. 111-xx Refresh detect test failed 112-xx Speed test slow mode out of range 113-xx Protected mode test failed. 114-xx Speaker test failed The following steps apply to 114-xx error codes: 1. Verify the speaker connection. 2. Replace the speaker and retest. 3. Replace the system board and retest. 116-xx Cache test failed Replace the system board and retest. 199-xx Installed devices test The following steps apply to 199-xx failed error codes: 1. Check the system configuration. 2. Verify cable connections. 3. Check switch and/or jumper settings. 4. Run the Configuration utility. 5. Replace the processor board and retest. 6. Replace the system board and retest. Table 3-3. Memory Test Error Codes Error Description Recommended Action Code 200-xx Invalid memory Reinsert memory modules in correct configuration location. 201-xx Memory machine ID test The following steps apply to error