HP ProSignia 500 Compaq ProSignia Family of PC Servers Maintenance and Service - Page 36
Table 3-13. Tape Drive Test Error Codes
![]() |
View all HP ProSignia 500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
1708-xx Fixed disk format bad track test failed 1709-xx Fixed disk reset controller test failed 1710-xx Fixed disk park head test failed 1715-xx Fixed disk head select test failed 1716-xx Fixed disk conditional format test failed 1717-xx Fixed disk ECC * test failed 1719-xx Fixed disk power mode test failed 1736-xx Drive Monitoring failed 1799-xx Invalid fixed disk drive type failed Error Correction Code Table 3-12. CD-ROM Drive Test Error Codes Error Description Recommended Action Code 1800-xx CD-ROM ID failed The following steps apply to error codes 1800-xx through 1823-xx: 1803-xx CD-ROM Power failed 1. Replace the CD-ROM and retest. 2. Check and/or replace the signal 1805-xx CD-ROM Read failed cable and retest. 3. Check the switch settings on the 1806-xx CD-ROM SA\Media failed adapter board (if applicable). 4. Replace the tape adapter board 1808-xx CD-ROM Controller (if applicable) and retest. failed 5. Replace the CD-ROM drive and retest. 1823-xx CD-ROM random read 6. Replace the system board and failed retest. Table 3-13. Tape Drive Test Error Codes Error Description Recommended Action Code 1900-xx Tape ID failed The following steps apply to error codes 1900-xx through 1906-xx: