Error ID: 66033: IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting Error ID: 66033: IDS - Overflow in light cyan main tank. Error Severity: Critical Possible Causes Real overflow event in main ink tank - drain main ink tank No real ink overflow - wrong reading due to main tank floater sensor problem Real overflow due to main ink pump stuck on continuous pumping No real ink overflow - wrong reading due to faulty MM4331 (1MM3) B&R control module No real ink overflow - wrong reading due to faulty DI9371 (1DI4) B&R module No real ink Overflow - wrong reading due to wiring disconnection FB10000 Error Messages Troubleshooting Troubleshooting Flowchart 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Error ID: 66033: IDS - Overflow in light cyan main tank.
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 66033: IDS - Overflow in light cyan main tank.
Error Severity:
Critical
Possible Causes
Real overflow event in main ink tank - drain main ink tank
No real ink overflow – wrong reading due to main tank floater sensor problem
Real overflow due to main ink pump stuck on continuous pumping
No real ink overflow – wrong reading due to faulty MM4331 (1MM3) B&R control module
No real ink overflow – wrong reading due to faulty DI9371 (1DI4) B&R module
No real ink Overflow – wrong reading due to wiring disconnection