HP Scitex FB10000 Geffen TS Error 66033 - Page 8
The DI9371 [1DI4] B&R module is faulty - replace module, Bus Unit BU
![]() |
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Error ID: 66033: IDS - Overflow in light cyan main tank. FB10000 Error Messages Troubleshooting DI9371 B&R module [1DI4] to which light cyan main tank overflow sensor is connected through cable CX161-02860 Top Flowchart The DI9371 [1DI4] B&R module is faulty - replace module Each B&R control module comprises three components: Base [4], Bus Unit (BU)[3], and Terminal block (12 PINS) [2]as shown below. When we say replacing a B&R module, we mean replacing only its Bus Unit which is the "configurable heart" of the module. 1. Go to the LEC and locate the DI9371 B&R control module labeled 1DI4 8
![](/manual_guide/products/hewlettpackard-scitex-fb10000-geffen-ts-error-66033-93cc0e9/8.png)
Error ID: 66033: IDS - Overflow in light cyan main tank.
FB10000 Error Messages Troubleshooting
DI9371 B&R module [1DI4] to which light cyan main tank overflow sensor is connected through cable CX161-02860
The DI9371 [1DI4] B&R module is faulty – replace module
Each B&R control module comprises three components: Base [
4
], Bus Unit (BU)[
3
], and Terminal block (12 PINS) [
2
]as shown below. When we say
replacing a B&R module, we mean replacing only its Bus Unit which is the “configurable heart” of the module.
1.
Go to the LEC and locate the DI9371 B&R control module labeled 1DI4
Top
Flowchart
8