HP Scitex FB10000 Geffen TS Error 66033 - Page 2

Troubleshooting Flowchart, Error ID: 66033: IDS - Overflow in light cyan main tank.

Page 2 highlights

Error ID: 66033: IDS - Overflow in light cyan main tank. Troubleshooting Flowchart FB10000 Error Messages Troubleshooting LC main tank overflow floater is mechanically stuck No Error ID: 66028: IDS - Overflow in LC main tank MM4331 (1MM3) B&R Module is faulty No Are the inputs in the DI9371 B&R module Off? In Control tools is the In Control Tools - is the Are the outputs in the No LC overflow main tank No LC main tank ink pump Yes MM4331(1MM3) B&R floater grayed? activated? module Off? Yes J4 LC main ink tank overflow floater cable is disconnected or damaged Yes The DI9371 (1DI4) B&R module is faulty Yes J5 cable is Shorted or damaged Flowchart Top 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Error ID: 66033: IDS - Overflow in light cyan main tank.
FB10000 Error Messages Troubleshooting
Troubleshooting Flowchart
Error ID: 66028: IDS - Overflow
in LC main tank
Yes
J5 cable
is Shorted or
damaged
Yes
In Control Tools - is the
LC main tank ink pump
activated?
No
No
Are the outputs in the
MM4331(1MM3) B&R
module Off?
Yes
No
Are the inputs in the
DI9371 B&R module
Off?
Yes
J4 LC main ink tank
overflow floater
cable is
disconnected or
damaged
No
The DI9371 (1DI4)
B&R module is faulty
In Control tools is the
LC overflow main tank
floater grayed?
LC main tank
overflow floater is
mechanically stuck
MM4331 (1MM3)
B&R Module is
faulty
Top
Flowchart
2