HP Scitex FB10000 Geffen TS Error 67009 - Page 2

Troubleshooting Flowchart

Page 2 highlights

Error ID: 67009: Safety - Bridge front door is open. Troubleshooting Flowchart Troubleshooting Flowchart for error messages 67013 - 67022 Safety interlocks Check the X20SI9100 pulses ouput Yes Is there More than 1 interlock OFF in this module? No Is the door open? No Check interlock Yes alignment Close the door and press the Reset button to continue Is the interlock properly aligned? Check Yes interlock and wiring No Adjust the interlock orientation and distance Are interlock and wiring OK? No Yes Replace interlock or interlock wiring Replace the faulty X20SI9100 module 2 Troubleshooting Top Flowchart

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Error ID: 67009: Safety - Bridge front door is open.
Troubleshooting
Top
Flowchart
Troubleshooting Flowchart
Troubleshooting Flowchart
for error messages 67013 – 67022
Safety interlocks
Is there More
than 1 interlock OFF in
this module?
No
Yes
Check
the X20SI9100
pulses ouput
Is the door open?
Close the door and press the
Reset button to continue
Yes
Check interlock
alignment
No
No
Replace interlock or
interlock wiring
Replace the
faulty
X20SI9100
module
Is the interlock
properly aligned?
Adjust the interlock
orientation and
distance
No
Check
interlock and
wiring
Yes
Are interlock and
wiring OK?
Yes
2