HP Scitex FB10000 Geffen TS Error 67009 - Page 6

Set the Safety PLC selector to 1 one new module and press the Enter button to instruct the Safety

Page 6 highlights

Error ID: 67009: Safety - Bridge front door is open. Step 1: Press the two latches (1) on top of the two TBs (2) and unplug them from the faulty BU. Step 2: Press the two latches (5) on top of the module BU (3) and unplug it from its base (4). Step 3: Plug the new BU (3) into its base (4). Step 4: Plug the two TBs (2) back into the BU (3) until you hear a click. Troubleshooting 7. Turn the machine on and configure the B&R Safety PLC to recognize and set the new module(s) as described below. Top Flowchart 8. Set the Safety PLC selector to 1 (one new module) and press the Enter button to instruct the Safety PLC to configure the new module. Upon completion, the MXCHG LED will blink orange single pulse and then will turn off to confirm that the module was configured. Note: This procedure takes up to two minutes. However, when the PLC encounters internal errors, it runs a full system scan and resets the entire system. This procedure takes between 40 to 60 minutes. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Error ID: 67009: Safety - Bridge front door is open.
Troubleshooting
7.
Turn the machine on and configure the B&R Safety PLC to recognize and set the new module(s) as described below.
8.
Set the Safety PLC selector to 1 (one new module) and press the Enter button to instruct the Safety PLC to configure the new module.
Upon completion, the MXCHG LED will blink orange single pulse and then will turn off to confirm that the module was configured.
Note: This procedure takes up to two minutes. However, when the PLC encounters internal errors, it runs a full system scan and
resets the entire system. This procedure takes between 40 to 60 minutes.
Step 1: Press the two latches (1) on top of the two TBs (2)
and unplug them from the faulty BU.
Step 2: Press the two latches (5) on top of the module BU
(3) and unplug it from its base (4).
Step 3: Plug the new BU (3) into its base (4).
Step 4: Plug the two TBs (2) back into the BU (3) until you
hear a click.
Top
Flowchart
6