Error ID: 67009: Safety - Bridge front door is open.

Page 4 highlights

Error ID: 67009: Safety - Bridge front door is open. Troubleshooting Door closed correct state Door open correct state 4. If the LEDS do not behave as shown above, this might indicate one of three: • The two parts of the interlock are not aligned • The cable is faulty • The interlock is faulty Receiver Transmitter 5. Check the yellow circular cable connecting the receiver to the B&R twice: with the door closed and with the door open. 6. With the door closed, disconnect the 2SDI2-SI17(13) white wire from the B&R module and the 2TBM-6(2) brown wire from the TBM block and check their continuity. You should get continuity between these two test points. Top 7. With the door open, disconnect the 2SDI2-SI18(23) (blue) wire from the B&R module and the 2TBM-8(2) (black) wire from the TBM block and check their continuity. With the door open you should get continuity between these two test points. Flowchart 8. If the results correspond to the above, then we know that the yellow circular cable and both parts of the interlock are ok. 9. If the results do not correspond, this might indicate that the interlock receiver is faulty. If this is the case, replace the receiver. 10. If the problem persists even after replacing the receiver, this indicates that the safety B&R module X20 SI9100 is faulty. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Error ID: 67009: Safety - Bridge front door is open.
Troubleshooting
Top
Flowchart
Door closed correct state
Door open correct state
4.
If the LEDS do not behave as shown above, this might indicate one of three:
The two parts of the interlock are not aligned
The cable is faulty
The interlock is faulty
5.
Check the yellow circular cable connecting the receiver to the B&R twice: with the door closed and with the door open.
6.
With the door closed, disconnect the 2SDI2-SI17(13) white wire from the B&R module and the 2TBM-6(2) brown wire from
the TBM block and check their continuity. You should get continuity between these two test points.
7.
With the door open, disconnect the 2SDI2-SI18(23) (blue) wire from the B&R module and the 2TBM-8(2) (black) wire from the
TBM block and check their continuity. With the door open you should get continuity between these two test points.
8.
If the results correspond to the above, then we know that the yellow circular cable and both parts of the interlock are ok.
9.
If the results do not correspond, this might indicate that the interlock receiver is faulty.
If this is the case, replace the receiver.
10.
If the problem persists even after replacing the receiver, this indicates that the safety B&R module X20 SI9100 is faulty.
Receiver
Transmitter