HP Scitex FB10000 Geffen TS Error 67009 - Page 7
If the MXCHG LED continues blinking orange single pulse every 5 seconds, please consult the detailed
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Error ID: 67009: Safety - Bridge front door is open. Troubleshooting 9. If the MXCHG LED continues blinking orange single pulse every 5 seconds, this indicates that the PLC failed to configure the new module (in case of 2 replaced modules, it will blink twice every 5 seconds etc.). Check if you have set the scan selector according to the number of new modules. Note: Interchanging two existing modules will be detected by the Safety PLC as two new modules. 10. If the MXCHG LED continues blinking orange single pulse every 5 seconds, please consult the detailed B&R PLC configuration guide, on page 4 for further instructions. 11. If none of the above steps solved the problem, contact your HP service specialist. Note: The diagram in the page below shows the tested components and provides a legend of the B&R naming conventions. Top Flowchart 7