HP Scitex FB700 HP Scitex FB500 and FB700 Printer Series - User Cleaning Instr - Page 7
Remove the service-end lamp housing
View all HP Scitex FB700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
2. Remove the four sliver screws (A and B in the following figure) that secure the lamp housing to the lower lamp assembly. Figure 3 User end screws B B A 3. LIft up to remove the lamp housing from the printer. Remove the service-end lamp housing 1. Disconnect the auxiliary cable from the top of the service-end lamp. See Figure 1 Disconnect the user-end auxiliary cable on page 4 for location. 2. Remove the lamp power cable from the side of the lamp housing by turning the coupling counterclockwise. See Figure 2 Remove the user-end power cable on page 4 for location. A ENWW Replace UV lamp bulb (500-1000 hours) 5
2.
Remove the four sliver screws (A and B in the following figure) that secure the lamp housing to
the lower lamp assembly.
Figure 3
User end screws
B
A
A
B
3.
LIft up to remove the lamp housing from the printer.
Remove the service-end lamp housing
1.
Disconnect the auxiliary cable from the top of the service-end lamp. See
Figure
1
Disconnect the
user-end auxiliary cable
on page
4
for location.
2.
Remove the lamp power cable from the side of the lamp housing by turning the coupling
counterclockwise. See
Figure
2
Remove the user-end power cable
on page
4
for location.
ENWW
Replace UV lamp bulb (500–1000 hours)
5