HP Scitex FB7600 TN Replacing the Printing Table - Page 16

The tolerance is, Release the screws on the table supports to allow inserting the shims.

Page 16 highlights

The tolerance is 0.3mm on one meter and 0.6mm for the entire table. You must to try to minimize the results to minimum difference. 6. If the measurements are not in the tolerance, you need to add shims between the table and table supports (or X motor support/slider). 7. Release the screws on the table supports to allow inserting the shims. Bad Shims Good

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

The tolerance is
0.3mm
on one meter and
0.6mm
for the entire table. You must to
try to minimize the results to minimum difference.
6.
If the measurements are not in the tolerance, you need to add shims between the
table and table supports (or X motor support/slider).
7.
Release the screws on the table supports to allow inserting the shims.
Bad
Good
Shims