HP Spectre 13-h200 HP Split 13 x2 PC Maintenance and Service Guide - Page 59

Volume button board, Release the ZIF connector

Page 59 highlights

Volume button board Description Volume button board (includes cable) NOTE: The volume button board does not include the volume button board cable. The volume button board cable is included in the Cable Kit, spare part number 736883-001. See Cable Kit on page 23 for more Cable Kit spare part information. Spare part number 736893-001 Before removing the volume button board, follow these steps: 1. Turn off the tablet. If you are unsure whether the tablet is off or in Hibernation, turn the tablet on, and then shut it down through the operating system. 2. Disconnect the power from the tablet by unplugging the power cord from the tablet. 3. Disconnect all external devices from the tablet. 4. Remove the back cover (see Back cover on page 38). 5. Remove the tablet battery (see Tablet battery on page 40). Remove the volume button board: 1. Release the ZIF connector (1) to which the volume button board cable is attached, and then disconnect the volume button board cable from the system board. 2. Remove the two Phillips PM2.0×3.0 screws (2) that secure the volume button board to the display assembly. Removal and replacement procedures 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Volume button board
Description
Spare part number
Volume button board (includes cable)
NOTE:
The volume button board does not include the volume button board cable. The volume
button board cable is included in the Cable Kit, spare part number 736883-001. See
Cable Kit
on page
23
for more Cable Kit spare part information.
736893-001
Before removing the volume button board, follow these steps:
1.
Turn off the tablet. If you are unsure whether the tablet is off or in Hibernation, turn the tablet on,
and then shut it down through the operating system.
2.
Disconnect the power from the tablet by unplugging the power cord from the tablet.
3.
Disconnect all external devices from the tablet.
4.
Remove the back cover (see
Back cover
on page
38
).
5.
Remove the tablet battery (see
Tablet battery
on page
40
).
Remove the volume button board:
1.
Release the ZIF connector
(1)
to which the volume button board cable is attached, and then
disconnect the volume button board cable from the system board.
2.
Remove the two Phillips PM2.0×3.0 screws
(2)
that secure the volume button board to the
display assembly.
Removal and replacement procedures