HP StorageWorks 2/128 Brocade Fabric OS Command Reference Manual (53-1000240-0 - Page 167
diagSkipTests
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
Note: Enter commands in lowercase only; mixed case is for readability. diagSkipTests 2 diagSkipTests Enables or disables diagnostics skip test flags. Synopsis diagskiptests [value | -show] Description Use this command to enable or disable the diagnostics skip test flags. The skip test flags are saved in flash memory and stay set until the next execution of diagSkipTests. The mode becomes active as soon as this command is executed. It does not require a reboot to take effect. The skip test flags are used to skip the execution of certain POSTs that might prove hazardous to normal switch operation. The exact use of this flag is determined by the POST scripts and the specific test methods used. Operands This command has the following operands: value Specify a bit mask for tests to skip. -show If specified or no value is given, the current skip test flags displays. If no operand is specified, the current value is displayed. Examples To display the current skip test flags: switch:admin> diagskiptests -show Skip tests is 1. See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-133