HP StorageWorks 2/128 Brocade Fabric OS Command Reference Manual (53-1000240-0 - Page 377
miniCycle, Diagnostics, To run a functional test on ports 0
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 377 highlights
Note: Enter commands in lowercase only; mixed case is for readability. miniCycle 2 To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment please ... Path 0 ... Spinning ... Path 1 ... skipped. Path 2 ... skipped. Path 3 ... skipped. Path 4 ... skipped. Path 5 ... skipped. Path 6 ... Spinning ... Path 7 ... Spinning ... Test Complete: "minicycle" Pass 1 of 1 Duration 0 hr, 0 min & 23 sec (0:0:23:100). passed. Diagnostics When it detects failure(s), the test reports one or more of the following error messages: DATA EPI1_STATUS_ERR ERR_STATS_2LONG ERR_STATS_BADEOF ERR_STATS_BADOS ERR_STATS_C3DISC ERR_STATS_CRC ERR_STATS_ENCIN ERR_STATS_ENCOUT ERR_STATS_TRUNC ERR_STAT_2LONG ERR_STAT_BADEOF ERR_STAT_BADOS ERR_STAT_C3DISC ERR_STAT_CRC ERR_STAT_ENCIN ERR_STAT_ENCOUT ERR_STAT_TRUNC FDET_PERR FINISH_MSG_ERR FTPRT_STATUS_ERR INIT LESSN_STATUS_ERR MBUF_STATE_ERR MBUF_STATUS_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-343