HP StorageWorks 4/256 Brocade Fabric OS Command Reference Manual - Supporting - Page 599
secModeEnable, option. With this option, the admin password is used for non-FCS admin
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 599 highlights
secModeEnable 2 secModeEnable Enables secure mode. Synopsis secmodeenable [--quickmode] | [[--currentpwd][--lockdown[=scc |=dcc]] [--fcs list_of_switches | list_of_switches]] Description Use this command to enable secure mode on all switches in the fabric. This command fails if any switch in the fabric is not capable of enforcing the security policies defined in the security database. If no operand is specified, the command becomes interactive. This command must be issued from a sectelnet or SSH session. Execute this command from the intended primary FCS. This command sets up security in the fabric by: Activating secure mode on all switches in the fabric. Creating the security database, populated with a list of FCS switches in the FCS_POLICY. Distributing the security database to all switches in the fabric. Resetting the root, factory, admin, and user account passwords on all FCS switches in the fabric. Resetting the admin and user account passwords on all non-FCS switches in the fabric. Disabling the root and factory accounts on all non-FCS switches in the fabric. The administrator is prompted to enter new passwords for the following accounts: • factory • root • admin • user • non-FCS admin The prompts do not display if the administrator chooses to use the passwords on the primary FCS with the --currentpwd option. With this option, the admin password is used for non-FCS admin as well. If the fabric is not in secure mode and one or more specified FCS switches is present in the fabric, the command must be issued on the first active FCS in the list. If the fabric is not in secure mode and no specified FCS switches are present in the fabric, the command can be issued on any switch. Only the --fcs option can be used in this case. If the fabric is not in secure mode and this command is issued, the switches in the fabric with Fabric OS versions previous to v4.4.0 or v3.2.0 reboots automatically. If the fabric is in secure mode and no FCS switches are present in the fabric, the command can be issued on any switch. This is used to recover a secure fabric that has no FCS switch. Only the --fcs option can be used in this case. Operands This command has the following operands: list_of_switches Specify a list of switches for the FCS policy. The list of switches must be enclosed in quotation marks, and each member switch must be separated from the others by semicolons. The members can be specified using domain, WWN, or switch name format, as follows: Fabric OS Command Reference Manual 567 53-1000436-01