HP StorageWorks 4/256 Brocade Fabric OS Command Reference Manual - Supporting - Page 87
burninLevel, viewed using
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
burninLevel 2 burninLevel Sets the diagnostics burn-in level. Synopsis burninlevel [level | -show] Description Use this command to select or display the burn-in level. When the burn-in level is set to a value other than 0, the diagnostic daemon program performs burn-in testing in place of the power-on self-test (POST) phase II each time a switch blade is powered on. The mode becomes active as soon as this command is executed so that it does not require a reboot to take effect. When a burn-in level other than 0 is selected, actual behavior is determined by the configuration of the diagnostics daemon and the burn-in scripts run. A useful application of this command is to store errors on the local persistent error storage on which the error occurs. This happens when the burn-in level is other than 0. This preserves the errors prior to returning a board for service. For multibladed products, this is the independent blade, and for fixed-port-count products, this is the chassis-persistent storage. The error logs are viewed using the burninErrShow command. Operands The following are optional: level The burn-in level sets to this value. -show If specified, or if level is not specified, the current burn-in level setting displays. Examples To set the diagnostic burn-in level: switch:admin> burninlevel -show Burnin level is 0. See Also burninErrShow, diagDisablePost, diagEnablePost, diagSetBurnin Fabric OS Command Reference Manual 55 53-1000436-01