HP StorageWorks 4/64 Brocade Error Message Reference Guide v6.1.0 (53-1000600- - Page 182
FCR-1012, FCR-1013, FCR-1015, FCR-1016
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 182 highlights
22 FCR-1012 FCR-1012 Message , [FCR-1012], ,, INFO, , FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port. Recommended No action is required. Action Severity INFO FCR-1013 Message , [FCR-1013], ,, INFO, , Phantom FSPF database exchange completed on port . Probable Cause Indicates that the specified EX_Port has completed the fabric shortest path first (FSFP) database exchange. Recommended No action is required. Action Severity INFO FCR-1015 Message , [FCR-1015], ,, INFO, , New EX_Port or VEX_Port added on port in domain . Probable Cause Indicates that an EX _Port was created on the specified port in the specified domain. Recommended No action is required. Action Severity INFO FCR-1016 Message , [FCR-1016], ,, INFO, , FCR fabric no longer reachable at port id fabric ID . Probable Cause Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link or switch failure. Recommended No action is required. Action Severity INFO 130 Fabric OS Message Reference 53-1000600-02