HP StorageWorks 4/64 Brocade Error Message Reference Guide v6.1.0 (53-1000600- - Page 81
AG-1023, to the attached F_Ports on edge switch is the same.
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
AG-1023 2 Probable Cause Indicates that the specified F_Port is failing over to its preferred N_Port. Recommended Please run ag --mapshow to display the updated F_Port to N_Port mapping. Action Severity INFO AG-1023 Message , [AG-1023], ,, INFO, , F_Port mapped to offline N_Port is failed over to its preferred N_Port . Probable Cause Indicates that the specified N_Port has failed to come online. F_Port mapped to this N_Port had its preferred set and is online. Recommended Run the ag --mapshow command to display updated F_Port to N_Port mapping. Action Severity INFO AG-1024 Message , [AG-1024], ,, INFO, , F_Port is failed back to its preferred N_Port . Probable Cause Indicates that the specified N_Port is failing back F_Ports, which are failed over to some other N_Port. Recommended Run the ag --mapshow command to display the updated F_Port to N_Port mapping. Action Severity INFO AG-1025 Message , [AG-1025], ,, ERROR, , Port group of Slave N_Port is different than its Master N_Port . Probable Cause Indicates that port group of Master and Slave N_Ports are different while the Trunk Area assigned to the attached F_Ports on edge switch is the same. Recommended Please run the porttrunkarea --show command on the attached switch to display that the TA is Action assigned to all ports in the system and run porttrunkarea --enable to reconfigure the TA. Severity ERROR Fabric OS Message Reference 29 53-1000600-02