HP StorageWorks 8/20q HP StorageWorks 8/20q Fibre Channel Switch event message - Page 15
An Update Fabric, Configuration SFC frame
View all HP StorageWorks 8/20q manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Table 4 Alarm events and recommended action (Continued) Icon Event ID and message Description Action (A1003.0021) (Failing remote zoning configuration, Zoneset is empty) An empty zone set was included as part of a zone merge and was rejected. Modify the zoning database on the remote switch to remove or correct the empty zone set. (A1003.0022) (Unable to update database with newly activated information, Zoning Save in Progress) Modifications were being made to the security or zoning database while a security set or zone set was being activated or deactivated from a remote switch. Try the activation or deactivation again later. (A1003.0023) (Fabric Busy Zoneset operation failed) The activation or deactivation Try the activation or of a zone set failed because deactivation again later. the fabric is currently busy. (A1003.0024) (Request already in progress (internal lock held)) (A1003.0025) (Error reading security set.) (A1003.0028) (SFC failure received from remote switch with domain domain_ID) (A1003.0029) (No response received from switch with domain ID domain_ID) A fabric operation is currently Wait and try again. in progress. There was a problem handling the activate direct management server command. The format of the command was not standard. Check the security configuration. The remote switch given by domain_ID rejected the Staged Fabric Configuration (SFC) message, so the SFC request has failed. Check the status of the remote switch at the given domain ID. There could be an issue with the security configuration or the zoning configuration. The remote switch given by domain_ID did not reply to an Acquire Change Authorization (ACA) message, so the ACA request has failed. Check the status of the remote switch at the given domain ID. There could be an issue with the security configuration or the zoning configuration. (A1003.002A) (No response received from switch with domain ID domain_ID) A Storage Fabric Configuration (SFC) frame was sent to the switch given by domain_ID, but a response was not received. Check the status of the remote switch at the given domain ID. There could be an issue with the security configuration or the zoning configuration. (A1003.002B) (No response received from switch with domain ID domain_ID) An Update Fabric Configuration (UFC) frame was sent to the switch given by domain_ID, but a response was not received. Check the status of the switch. (A1003.002C) (Zone Merge response indicates failure due to zoning limits, Isolating link) Response from other switch indicates that the active zone sets could not be merged. Edit or delete the conflicting zone objects or deactivate the zone set on the remote switch. 8/20q Fibre Channel Switch event messages reference guide 15