HP StorageWorks XP12000 HP StorageWorks XP Disk Array Configuration Guide: HP- - Page 15

Verifying FCA installation, Verifying device recognition, HP StorageWorks XP LUN Manager User, s Guide

Page 15 highlights

In XP Command View Advanced Edition Software, LUN mapping includes: • Configuring ports • Creating storage groups • Mapping volumes and WWN/host access permissions to the storage groups For details see the HP StorageWorks XP LUN Manager User's Guide or the HP StorageWorks XP Command View Advanced Edition Software Device Manager Web Client User's Guide. Note the LUNs and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and device configuration. Verifying FCA installation After configuring the ports on the disk array, verify that the FCAs are installed properly. Use the ioscan -f command, and verify that the rows shown in the example are displayed. If these rows are not displayed, check the host adapter installation (hardware and driver installation) or the host configuration. Example # ioscan -f Class I H/W Path ... fc 0 8/12 lan 1 8/12.5 fcp 0 8/12.8 ext bus 2 8/12.8.0.255.0 Driver S/W State H/W Type Description fcT1 CLAIMED fcT1_cntl CLAIMED fcp CLAIMED fcpdev CLAIMED INTERFACE HP Fibre ... INTERFACE HP Fibre ... INTERFACE FCP Proto... INTERFACE FCP Devic... Verifying device recognition Verify that the HP-UX system recognizes the new devices on the disk array. If the SCSI paths were defined after the system is powered on, you must halt and restart the system to allow the system to recognize the new devices. XP Disk Array Configuration Guide for HP-UX 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

In XP Command View Advanced Edition Software, LUN mapping includes:
Configuring ports
Creating storage groups
Mapping volumes and WWN/host access permissions to the storage groups
For details see the
HP StorageWorks XP LUN Manager User
s Guide
or the
HP StorageWorks XP
Command View Advanced Edition Software Device Manager Web Client User
s Guide
. Note the
LUNs and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and device
configuration.
Verifying FCA installation
After configuring the ports on the disk array, verify that the FCAs are installed properly.
Use the
ioscan
f
command, and verify that the rows shown in the example are displayed. If these
rows are not displayed, check the host adapter installation (hardware and driver installation) or the
host configuration.
Example
# ioscan
f
Class
I H/W Path
Driver
S/W State H/W Type
Description
...
fc
0 8/12
fcT1
CLAIMED
INTERFACE HP Fibre ...
lan
1 8/12.5
fcT1_cntl CLAIMED
INTERFACE HP Fibre ...
fcp
0 8/12.8
fcp
CLAIMED
INTERFACE FCP Proto...
ext bus
2 8/12.8.0.255.0
fcpdev
CLAIMED
INTERFACE FCP Devic...
Verifying device recognition
Verify that the HP-UX system recognizes the new devices on the disk array.
If the SCSI paths were defined after the system is powered on, you must halt and restart the system
to allow the system to recognize the new devices.
XP Disk Array Configuration Guide for HP-UX
15