HP Surestore Disk Array 12h Storage Manager 60-NT User’s Guide - Page 96
For example, if Node A had an internal hard disk at drive letter C: and Node B had two internal
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
Drive letters of shared volumes do not match in Disk Administrator on both nodes. CAUSE The wrong letters were assigned during installation. ACTION Use the in the Disk Administrator on the appropriate node to ensure that the drive letters are the same as those assigned to node A. For example, if Node A had an internal hard disk at drive letter C: and Node B had two internal hard disks at C: and D:, then the shared disk letters would not match (Node A would start at drive D: and Node B would start at drive E:; therefore, you would have to change the drive letter at Node A to start at drive E:). 96
96