HP Surestore Disk Array 12h Storage Manager 60-NT User’s Guide - Page 96

For example, if Node A had an internal hard disk at drive letter C: and Node B had two internal

Page 96 highlights

Drive letters of shared volumes do not match in Disk Administrator on both nodes. CAUSE The wrong letters were assigned during installation. ACTION Use the in the Disk Administrator on the appropriate node to ensure that the drive letters are the same as those assigned to node A. For example, if Node A had an internal hard disk at drive letter C: and Node B had two internal hard disks at C: and D:, then the shared disk letters would not match (Node A would start at drive D: and Node B would start at drive E:; therefore, you would have to change the drive letter at Node A to start at drive E:). 96

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

96
±±±±±±±±&OXVWHU±6HUYHU±7URXEOHVKRRWLQJ
*R±WR±
¿:KDWªV±1H[W"¿±RQ±SDJH ³Á
´
Drive letters of shared volumes do
not
match in Disk Administrator on both nodes.
C
AUSE
The wrong letters were assigned during installation.
A
CTION
Use the
7RROV±!!±$VVLJQ±'ULYH±/HWWHUV
in the Disk Administrator on the appropriate
node to ensure that the drive letters are the same as those assigned to node A.
For example, if Node A had an internal hard disk at drive letter C: and Node B had two internal
hard disks at C: and D:, then the shared disk letters would not match (Node A would start at drive
D: and Node B would start at drive E:; therefore, you would have to change the drive letter at
Node A to start at drive E:).
7DEOH±Â
±
&OXVWHU±6HUYHU±7URXEOHVKRRWLQJ±±ÂFRQWªGÃ