Hitachi 7K250 Specifications - Page 49
Connector locations, Drive mounting, Heads unload and actuator lock
![]() |
UPC - 000004558972
View all Hitachi 7K250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
6.5.3 Connector locations Figure 9: Connector locations 6.5.4 Drive mounting The drive will operate in all axes (6 directions). Performance and error rate will stay within specification limits if the drive is operated in the other orientations from which it was formatted. For reliable operation, the drive must be mounted in the system securely enough to prevent excessive motion or vibration of the drive during seek operation or spindle rotation, using appropriate screws or equivalent mounting hardware. The recommended mounting screw torque is 0.6 - 1.0 Nm (6-10 Kgf.cm). The recommended mounting screw depth is 4 mm maximum for bottom and 4.5 mm maximum for horizontal mounting. Drive level vibration test and shock test are to be conducted with the drive mounted to the table using the bottom four screws. 6.5.5 Heads unload and actuator lock The head load/unload mechanism is provided to protect the disk data during shipping, movement, or storage. Upon power down, the heads are automatically unload from the disk area and the locking mechanism of the head actuator will secure the heads in unload position. Deskstar 7K250 Hard Disk Drive Specification 35