Hitachi CP-X440 User Manual - Page 42

Troubleshooting - instructions

Page 42 highlights

Troubleshooting Troubleshooting Related messages When the unit's power is on, messages such as those shown below may be displayed. When any such message is displayed on the screen, please follow the instructions described below. If the same message is displayed after the remedy, or if a message other than the following appears, please contact your dealer or service company. Although these messages will be automatically disappeared around several minutes, it will be reappeared every time the power is turned on. Message CHANGE THE LAMP. AFTER REPLACING LAMP, RESET THE LAMP TIMER. CHANGE THE LAMP. AFTER REPLACING LAMP, RESET THE LAMP TIMER. THE POWER WILL BE TURNED OFF ** hrs later. CHANGE THE LAMP. AFTER REPLACING LAMP, RESET THE LAMP TIMER. THE POWER WILL BE TURNED OFF 0 hrs later. NO INPUT IS DETECTED ON *** SYNC IS OUT OF RANGE ON *** fH *****kHz fV *****Hz Description The time the lamp timer has counted is approaching 2000 hours. Preparation of a new lamp and an early lamp change are recommended. After you have changed the lamp, please be sure to reset the lamp timer(36). The time the lamp timer has counted is approaching 2000 hours, so a lamp change within ** hours is recommended. When lamp usage reaches 2000 hours, the power will automatically be turned off. Please change the lamp by referring to the section "Lamp". After you have changed the lamp, please be sure to reset the lamp timer(36). As the time the lamp timer has counted has reached 2000 hours, the power will soon be automatically turned off. Please immediately turn the power off, and change the lamp by referring to the section "Lamp". After changing the lamp, please be sure to reset the lamp timer(36). There is no input signal. Please confirm the signal input connection, and the status of the signal source. The horizontal or vertical wavelength of the input signal is out of the response parameter range of this unit. Please confirm the specs for your projector or the signal source specs. 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49

42
Troubleshooting
Troubleshooting
Related messages
When the unit's power is on, messages such as those shown below may be
displayed. When any such message is displayed on the screen, please follow the
instructions described below. If the same message is displayed after the remedy,
or if a message other than the following appears, please contact your dealer or
service company.
Although these messages will be automatically disappeared around several
minutes, it will be reappeared every time the power is turned on.
Message
Description
CHANGE THE LAMP.
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
The time the lamp timer has counted is approaching
2000 hours.
Preparation of a new lamp and an early lamp change are
recommended. After you have changed the lamp, please be
sure to reset the lamp timer(
36
).
CHANGE THE LAMP.
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL BE
TURNED OFF ** hrs later.
The time the lamp timer has counted is approaching
2000 hours, so a lamp change within
**
hours is
recommended.
When lamp usage reaches 2000 hours, the power will
automatically be turned off. Please change the lamp by
referring to the section “Lamp”. After you have changed the
lamp, please be sure to reset the lamp timer(
36
).
CHANGE THE LAMP.
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL BE
TURNED OFF 0 hrs later.
As the time the lamp timer has counted has reached
2000 hours, the power will soon be automatically
turned off.
Please immediately turn the power off, and change the lamp
by referring to the section “Lamp”. After changing the lamp,
please be sure to reset the lamp timer(
36
).
NO INPUT IS DETECTED
ON ***
There is no input signal.
Please confirm the signal input connection, and the status
of the signal source.
SYNC IS OUT OF RANGE
ON ***
fH
*****kHz
fV
*****Hz
fH
*****kHz
fV
The horizontal or vertical wavelength of the input signal
is out of the response parameter range of this unit.
Please confirm the specs for your projector or the signal
source specs.