Honeywell 3800ISR050-0F00E User Manual - Page 145
Standard Cable Pinouts, Laser Output Only Laser Compatible Bar Image
View all Honeywell 3800ISR050-0F00E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Standard Cable Pinouts Laser Output Only (Laser Compatible Bar Image) 3800i/3800r User's Guide ◆ Pins 4 and 9 are populated depending on power supply voltage option. connects to your terminal 9 Pin Type D Female Start of scan 1 Digital bar code data output 2 Turn on good read LED or beeper 3 ◆ N/C 4 Trigger signal to decoder 5 6 Laser enable 7 Supply ground 8 Cord shield 9 5 Volt power connection ◆ connects to the scanner handle 10 Pin Modular Plug 1 Turn on good read or LED beeper 2 Trigger signal to decoder 3 Laser enable 4 Supply ground 5 6 Digital bar code data output 7 Supply input power (Refer to tables on page 12-1 and page 12-3) 8 9 Start of scan 10 Conventional laser data format is provided at the modular connector in the scanner handle. The interface cable is terminated with a 10 pin modular plug, and a 9 pin Type D (squeeze to release) connector that is compatible with all Hand Held Products terminals. 12 - 5