Honeywell 3800ISR050-0F00E User Manual - Page 68
Data Format Editor, Syntax = FC, tax = E4nnxx
View all Honeywell 3800ISR050-0F00E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
zz is the list of characters to be suppressed. (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252) on page A2.) FC Disables suppress filter and clear all suppressed characters. Syntax = FC. E4 Replaces up to 15 characters in the data string with user specified characters. Replacement continues until the E5 command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of both characters to be replaced plus replacement characters; xx1 defines characters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2. E5 Terminates character replacement. Syntax = E5. FE Compare character in current cursor position to the character "xx." If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FExx (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252) on page A-2.) EC Check to make sure there is an ASCII number at the current cursor position. If character is not numeric, format is aborted. Syntax = EC. ED Check to make sure there is a non-numeric ASCII character at the current cursor position. If character is numeric, format is aborted. Syntax = ED. Data Format Editor Enter Data Format Clear One Data Format Save * Default Data Format Clear All Data Formats Discard 5 - 4 3800i/3800r User's Guide