Honeywell HCM6011I Owners Manual - Page 8

Power, Step 1: Power, Step 2: Output / Fan Speed Control, Step 3: Timer Control

Page 8 highlights

Digital EasySet™ Control Operation (Model HCM-6012 & HCM-6012-CST) POWER CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRICAL SHOCK COULD OCCUR. • With the power OFF, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way. STEP 1: POWER • Press the Power button to start the humidifier. Your humidifier will automatically start on High power, Continuous Mode. The display will be illuminated and will reflect the current room humidity (Fig. 10). • To turn your humidifier OFF simply press the Power button again. Fig. 10 Desired Humidity Light Fan Speed Control Humidistat Control Timer Control STEP 2: OUTPUT / FAN SPEED CONTROL Your unit has three output levels/fan speeds: HIGH: For fast humidifying MED: For everyday moisture control LOW: For minimum operation (ideal for nighttime use) Fig. 11 • To change your fan speed press the fan speed button ( ) up or down (Fig. 11). • Once you have selected your desired speed the display will go back to showing the current room humidity after 3 seconds. NOTE: If you wish to change or check your output/speed setting simply press the fan speed button ( ) once and it will show you your setting. If you would like to change it, continue to push the button up or down until you have reached your desired setting. Again, after 3 seconds the display will revert to showing the current room humidity. Fig. 12 NOTE: Turn the humidifier off if the humidity level feels too moist or you notice condensation forming on the walls. STEP 3: TIMER CONTROL • You can set your timer for up to 18 hours. This function should only be used if you desire that the humidifier be automatically shut off after a certain period of time. • Press the Timer button ( ) up or down to set how many hours you would like the humidifier to run (Fig. 12). • When the display indicates your desired time, wait 3 seconds. • After 3 seconds, your desired time is set and the display will revert back to showing the current room humidity. NOTE: If you wish to change your timer setting or check to see how much time is left, simply press the Timer button ( ) once and it will show you the time left. If you want to change the time remaining, continue to push the button up or down until you have reached your desired time. Again, after 3 seconds the display will revert to showing the current room humidity. If you set a timer but no longer wish to have it set, turn the unit off and then repeat steps 1 and 2. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

8
POWER
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET
HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.
With the power OFF, plug the filled humidifier into a polarized 120V
outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it
will only fit one way.
STEP 1: POWER
Press the Power button to start the humidifier. Your humidifier will
automatically start on High power, Continuous Mode. The display
will be illuminated and will reflect the current room humidity
(Fig. 10).
To turn your humidifier OFF simply press the Power button again.
STEP 2: OUTPUT / FAN SPEED CONTROL
Your unit has three output levels/fan speeds:
HIGH: For fast humidifying
MED: For everyday moisture control
LOW: For minimum operation (ideal for nighttime use)
To change your fan speed press the fan speed button (
) up or
down (Fig. 11).
Once you have selected your desired speed the display will go back
to showing the current room humidity after 3 seconds.
NOTE:
If you wish to change or check your output/speed setting simply
press the fan speed button (
) once and it will show you your setting.
If you would like to change it, continue to push the button up or down
until you have reached your desired setting. Again, after 3 seconds the
display will revert to showing the current room humidity.
NOTE: Turn the humidifier off if the humidity level feels too moist
or you notice condensation forming on the walls.
STEP 3: TIMER CONTROL
You can set your timer for up to 18 hours. This function should only
be used if you desire that the humidifier be automatically shut off
after a certain period of time.
Press the Timer button (
) up or down to set how many hours you
would like the humidifier to run (Fig. 12).
When the display indicates your desired time, wait 3 seconds.
• After 3 seconds, your desired time is set and the display will revert back to showing the current room
humidity.
NOTE:
If you wish to change your timer setting or check to see how much time is left, simply press the
Timer button (
) once and it will show you the time left. If you want to change the time remaining,
continue to push the button up or down until you have reached your desired time. Again, after 3 seconds
the display will revert to showing the current room humidity.
If you set a timer but no longer wish to have
it set, turn the unit off and then repeat steps 1 and 2.
Digital EasySet
Control Operation (Model HCM-6012 & HCM-6012-CST)
Fig. 10
Fig. 11
Fig. 12
Humidistat
Control
Fan Speed
Control
Timer
Control
Desired
Humidity
Light