Honeywell T8611 Owner's Manual - Page 7
Honeywell T8611 Manual
View all Honeywell T8611 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
The oroaram times are the same for bbthheating and cooling. Only the cooling temperatures need to be programmed if you have already programmed for heating. To set ti~mes as you program the cooling temperatures, use the TIME AHEAD and BACK keys as described in Step 2. But if you change times for cooling, you are also changing them for heating! First program the WAKE temperature for weekdays. Press and release. The display shows WAKE and the time and temperature you programmed for heating. 1_533-1 Press and release so COOL shows on the display, along with the preprogrammed cooling temperature. If display reads SAT or SUN, press and hold until MON TUE WED THU FRI appears. Press and hold until the display shows the desired temperature. If the display blinks while you hold down TEMPERATURE WARMER or COOLER, you have reached the setting limit. If your thermostat can switch automatically between heating and cooling, the cooling temperature must be at least 3 degrees higher than the corresponding heating temperature. For example, if the heating setting is 70' F, the minimum cooling setting is 73" F. If you desire a lower cooling temperature, the heating temperature must first be lowered accordingly. 10