Honeywell T8775C1005 Installation Instructions - Page 4
Caution - digital round non programmable thermostat
UPC - 085267244183
View all Honeywell T8775C1005 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
T8775A,C THE DIGITAL ROUND™ NON-PROGRAMMABLE THERMOSTATS (T8775C ONLY) SELECTS COOL/OFF/HEAT (T8775C ONLY) SELECTS ON/AUTO ROOM SHOWS THAT THE SET CURRENT ROOM TEMPERATURE IS DISPLAYED. DISPLAYS ROOM OR SET TEMPERATURE SHOWS THAT THE CURRENT TEMPERATURE SETPOINT IS DISPLAYED. DISPLAYS AND ADJUSTS TEMPERATURE SETPOINT/TURNS BACKLIGHT ON M19520 Fig. 10. T8775 Thermostat (features and operation). SYSTEM Switch Heat: Off: Cool: The thermostat controls the heating system. Both heating and cooling systems are off. The thermostat controls the cooling system. FAN Switch Auto: On: The fan only runs with the heating and cooling system. The fan runs continuously. Use for improved air circulation. CHECKOUT NOTE: Temperature setpoint range is 40°F to 90°F (4°C to 32°C) in heating and 45°F to 99°F (7°C to 37°C) in cooling. Heating 1. Slide the SYSTEM switch to Heat and the FAN switch to Auto (T8775C only). 2. Raise the temperature setpoint several degrees above the room temperature. 3. A flame will appear in the display and the heat should turn on. 4. Lower the temperature setpoint below the room temperature. 5. The flame will disappear from the display and the heat should turn off. Cooling (T8775C only) CAUTION Low Temperature Hazard. Operating at too low of an outdoor temperature may cause compressor damage. Do not operate cooling if outdoor temperature is below 50°F (10°C). Refer to manufacturer's recommendations. NOTE: If a call for cooling is made before the compressor has been off for five minutes, or if a power interruption occurs while the compressor is running, the thermostat will go into a five-minute delay to protect the compressor. The snowflake will flash during this delay. 1. Slide the SYSTEM switch to Cool and the FAN switch to Auto. 2. Lower the temperature setpoint several degrees below the room temperature. 3. After approximately five minutes, the thermo- stat will display a solid snowflake and the cooling should turn on. 4. Raise the temperature setpoint above the room temperature. 5. The snowflake will disappear from the display and the cooling should turn off. Fan 1. Slide the SYSTEM switch to Off and the FAN switch to On. The fan should run continuously. 2. Slide the FAN switch to Auto. The fan should turn off. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 69-1677EF-1 J.S. Rev. 6-04 Printed in Hungary www.honeywell.com/yourhome