Honeywell TE653ELW User Manual - Page 9

Auto-scanning, Programmable Temperature Alarm, Comfort Level Indicators - m manual

Page 9 highlights

The indoor temperature and humidity with the icon IN are located below the remote temperature and humidity information line. NOTE: If the indoor or remote temperature or humidity goes above or below operating range stated in specifications, the main unit's display ( weather) will show dashes "- - -" on the corresponding line. AUTO-SCANNING Press and hold the CHANNEL button for 2 seconds - the icon "3" will appear on the main unit display to the left of the COMFORT LEVEL indicator. All three remote channels data will be displayed one-by-one automatically with 11 seconds delay in the following sequence: Channel 1, Channel 2 and Channel 3. To exit from scanning mode, press and hold the CHANNEL button for 2 seconds, and the icon "3" will disappear, returning the main unit display to the default display mode. PROGRAMMABLE TEMPERATURE ALARM This product allows manual programming of a HIGH and LOW temperature alarms for all three remote channels at the same time. Once the actual remote temperature will reach the pre-set high or low limits, the alarm will sound. The alarm can be set for temperature readings between -58 °F and 158°F. To program the temperature alarm for all three remote channels, • Press the TEMP ALARM button once to enter into the High Temperature Alarm programming mode - the abbreviation "OF" with the high temperature limit symbol ( ▲) will be displayed on the remote temperature line • Press and hold TEMP ALARM button until the abbreviation "OF" will 17 flash • Use UP( ▲) or DOWN(T) arrow buttons to adjust the higher temperature limit • Press the TEMP ALARM button to confirm the selected value • Press the TEMP ALARM button once to enter into the Low Temperature Alarm programming mode - the abbreviation "OF" with the low temperature limit symbol (T) will be displayed on the remote temperature line • Press and hold TEMP ALARM button until the abbreviation "OF" will flash • Use UP( ▲) or DOWN(T) arrow buttons to adjust the lower temperature limit • Press the TEMP ALARM button to confirm the selected value COMFORT LEVEL INDICATORS This product is capable of detecting and displaying the current indoor comfort levels of surrounding environment. The comfort level is displayed in the weather station portion of the main unit's display. It is based on the combination of the current indoor temperature and humidity readings. There are following comfort levels may be displayed: COMFORT (comfortable); WET (wet) and DRY (dry) Indicator displayed COMFORT Temperature Range 20°C to 25°C (68°F to 77°F) Humidity Range 40%RH70%RH Shows current condition Ideal for both relative humidity and temperature 17 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

17
17
The indoor temperature and humidity with the icon
IN
are located below the
remote temperature and humidity information line.
NOTE
: If the indoor or remote temperature or humidity goes above or below
operating range stated in specifications, the main unit’s display ( weather) will
show dashes “- - -” on the corresponding line.
AUTO-SCANNING
Press and hold the
CHANNEL
button for 2 seconds – the icon “
3
will
appear on the main unit display to the left of the
COMFORT LEVEL
indicator.
All three remote channels data will be displayed one-by-one automatically with
11 seconds delay in the following sequence: Channel 1, Channel 2 and
Channel 3.
To exit from scanning mode, press and hold the
CHANNEL
button for 2
seconds, and the icon “
3
” will disappear, returning the main unit display to the
default display mode.
PROGRAMMABLE TEMPERATURE ALARM
This product allows manual programming of a
HIGH
and
LOW
temperature
alarms for all three remote channels at the same time. Once the actual remote
temperature will reach the pre-set high or low limits, the alarm will sound. The
alarm can be set for temperature readings between -58 °F and 158°F.
To program the temperature alarm for all three remote channels,
Press the
TEMP
ALARM
button once to enter into the
High
Temperature
Alarm
programming mode – the abbreviation “
OF”
with
the high
temperature limit symbol
(
)
will be displayed on the remote
temperature line
Press and hold
TEMP ALARM
button until the abbreviation “
OF
” will
18
flash
Use
UP
(
) or
DOWN
(
T
) arrow buttons to adjust the higher
temperature limit
Press the
TEMP
ALARM
button to confirm the selected value
Press the
TEMP
ALARM
button once to enter into the
Low
Temperature Alarm
programming mode – the abbreviation “
OF”
with
the low temperature limit symbol
(
T
)
will be displayed on the remote
temperature line
Press and hold
TEMP ALARM
button until the abbreviation “
OF
” will
flash
Use
UP
(
) or
DOWN
(
T
) arrow buttons to adjust the lower
temperature limit
Press the
TEMP
ALARM
button to confirm the selected value
COMFORT LEVEL INDICATORS
This product is capable of detecting and displaying the current indoor comfort
levels of surrounding environment. The comfort level is displayed in the
weather station portion of the main unit’s display. It is based on the combination
of the current indoor temperature and humidity readings. There are following
comfort levels may be displayed:
COMFORT
(comfortable);
WET
(wet) and
DRY
(dry)
Indicator
displayed
Temperature
Range
Humidity
Range
Shows current
condition
COMFORT
20°C to 25°C
(68°F to
77°F)
40%RH-
70%RH
Ideal for both relative
humidity and
temperature