Hoover U5146-900 Owners Manual - Page 10

Belt replacement, Headlight replacement

Page 10 highlights

Headlight replacement 3-8 3-9 What to buy This cleaner uses a 12 volt, wedge base type 912 bulb, HOOVER part No. 27313101. 3-7 Install bulb - Pull old bulb straight out of socket. Push new bulb straight into socket until locked in place. Excessive force is not required. Remove lens - Disconnect cleaner from electrical outlet. Using a screwdriver, remove the two screws as shown and lift off lens. Belt replacement The belt on your Hoover cleaner causes the agitator to rotate and is important for the effective operation of the cleaner. The belt is located under the bottom plate of the cleaner and should be checked from time to time to be sure it is in good condition. When to replace Disconnect cleaner from electrical outlet. To check belt, remove bottom plate as shown in "How to replace". Replace belt if it is stretched, cut or broken. What to buy To assure effective operation, use only genuine HOOVER belts with your cleaner. When purchasing a new belt, ask for HOOVER part No. 38528033 (belt package part number 40201160). 3-10 A How to replace Disconnect cleaner from electrical outlet. Remove bottom plate Place handle in low position and turn cleaner over so bottom side is up. Remove the 4 screws as shown with a Phillips screwdriver. Lift off bottom plate (A). Replace lens - Reposition lens and secure with the two screws. 3-11 Remove agitator brush roll Remove agitator and used belt. Discard used belt. 3-12 C 3-13 D 3-14 B Install new belt With lettering on outside of belt and positioned as shown in box on (B), slide new belt over motor pulley (C). 10 F E Replace agitator brush roll Insert agitator through belt and place belt in belt guide (D) on agitator. Should the agitator shield (E) become dislodged while replacing the belt or the agitator, reposition it as shown noting the placement of its belt guide (F). G H Secure agitator Grasp agitator firmly and fit it into position by first sliding end opposite the belt into the rectangular slot (G) on side of cleaner. Pull other side of agitator (H) into place. Turn agitator making sure belt is not pinched between agitator and agitator shield.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

10
3-9
3-10
Remove agitator brush roll
Remove agitator and used belt.
Discard used belt.
Replace lens -
Reposition lens and
secure with the two screws.
How to replace
Disconnect cleaner from electrical
outlet.
Remove bottom plate
Place handle in low position and turn
cleaner over so bottom side is up.
Remove the 4 screws as shown with a
Phillips screwdriver.
Lift off bottom plate (A).
Install new belt
With lettering on outside of belt and
positioned as shown in box on (B), slide
new belt over motor pulley (C).
3-11
3-14
3-12
3-13
C
D
E
A
F
B
G
H
Replace agitator brush roll
Insert agitator through belt and place
belt in belt guide (D) on agitator.
Should the agitator shield (E) become
dislodged while replacing the belt or the
agitator, reposition it as shown noting the
placement of its belt guide (F).
Belt replacement
The belt on your Hoover cleaner causes
the agitator to rotate and is important for
the effective operation of the cleaner.
The belt is located under the bottom
plate of the cleaner and should be
checked from time to time to be sure it is
in good condition.
When to replace
Disconnect cleaner from electrical
outlet.
To check belt, remove bottom plate as
shown in “How to replace”. Replace belt
if it is stretched, cut or broken.
What to buy
To assure effective operation, use only
genuine HOOVER belts with your
cleaner. When purchasing a new belt,
ask for
HOOVER part No. 38528033
(belt package part number 40201160).
Secure agitator
Grasp agitator firmly and fit it into posi-
tion by first sliding end opposite the belt
into the rectangular slot (G) on side of
cleaner.
Pull other side of agitator (H) into place.
Turn agitator making sure belt is not
pinched between agitator and agitator
shield.
Remove lens -
Disconnect clean-
er from electrical outlet.
Using a screwdriver, remove the two
screws as shown and lift off lens.
3-8
3-7
Headlight replacement
What to buy
This cleaner uses a 12 volt, wedge base
type 912 bulb,
HOOVER part No.
27313101.
Install bulb -
Pull old bulb straight
out of socket.
Push new bulb straight
into socket until locked in place.
Excessive force is not required.