Edge groomer replacement When to replace The edge groomers, located on both sides of the nozzle, should be replaced when they are worn. What to buy When purchasing edge groomers, ask for HOOVER part No. 39511004. How to replace Disconnect cleaner from electrical outlet. Remove bottom plate as described in "The belt" section (Fig.3-18). 3-37 Installing groomers Lift off both old edge groomers and slide new edge groomers into position as shown. Reposition bottom plate and secure with (4) Phillips head screws. Lubrication The motor is equipped with bearings which contain sufficient lubrication for the life of the motor. The addition of lubricant could cause damage. Do not add lubricant to motor bearings. The agitator is equipped with two ball bearings that should be lubricated periodically by a Hoover Factory Service Center or an Authorized Hoover Warranty Service Dealer (Depot). Thermal protector An internal thermal protector has been designed into your cleaner to protect it from overheating. When the thermal protector activates, the cleaner will stop running. If this happens, proceed as follows: 1. Turn the cleaner OFF and disconnect it from the electrical outlet. 2. Check dirt cup pre-filter, HEPA cartridge filter and secondary and final filters for dirt accumulation. 3. Refer to "Clearing blockages" section. 4. When cleaner is unplugged and the motor cools for 30 minutes, the thermal protector automatically resets and cleaning may continue. If the thermal protector continues to activate after following the above steps, your cleaner may need servicing (see "Service" section). Service To obtain approved HOOVER service and genuine HOOVER parts, locate the nearest Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer (Depot) by: • checking the Yellow Pages under "Vacuum Cleaners - Household" OR - • checking the list of Factory Service Centers provided with this cleaner OR - • checking the Service section of The Hoover Company on-line at www.hoover.com OR - • calling 1-800-944-9200 for an automated referral of authorized service outlet locations (U.S. only). Do not send your cleaner to The Hoover Company in North Canton for service, this will only result in delay. If further assistance is needed, contact The Hoover Company Consumer Response Center, North Canton, Ohio 44720, Phone: 330-499-9499. In Canada, contact Hoover Canada, Burlington, Ontario L7R 4A8, Phone: 1-800-263-6376. Always identify your cleaner by the complete model number when requesting information or ordering parts. (The model number appears on the bottom of the cleaner.) Hoover Cleaning Performance This Hoover Cleaning Performance System is for comparing the relative progressive performance of Hoover uprights only and not for comparison with any other brands. The majority of this rating is based upon the American Society for Testing and Materials (ASTM) Carpet Cleaning Effectiveness Test (ASTM Test F608). Other performance factors include Hose Power (ASTM Test F558), Surface Litter Cleaning, Hard Floor Cleaning, Edge Cleaning, Cleaning Width and Air Filtration. Continued 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

3-37
13
Edge groomer
replacement
When to replace
The edge groomers, located on both
sides of the nozzle, should be replaced
when they are worn.
What to buy
When purchasing edge groomers, ask
for HOOVER
part No. 39511004.
How to replace
Disconnect cleaner from electrical
outlet.
Remove bottom plate as described in “The
belt” section (Fig.3-18).
Installing groomers
Lift off both old edge groomers and slide
new edge groomers into position as
shown.
Reposition bottom plate and secure with
(4) Phillips head screws.
Lubrication
The motor is equipped with bearings
which contain sufficient lubrication for
the life of the motor. The addition of
lubricant could cause damage.
Do not
add lubricant to motor bearings.
The agitator is equipped with two ball
bearings that should be lubricated
periodically by a Hoover Factory
Service Center or an Authorized Hoover
Warranty Service Dealer (Depot).
Thermal protector
An internal thermal protector has been
designed into your cleaner to protect it
from overheating.
When the thermal protector activates,
the cleaner will stop running.
If this
happens, proceed as follows:
1. Turn the cleaner OFF and discon-
nect it from the electrical outlet.
2. Check dirt cup pre-filter, HEPA car-
tridge filter and secondary and final fil-
ters for dirt accumulation.
3. Refer to “Clearing blockages” sec-
tion.
4.
When cleaner is unplugged and
the motor cools for 30 minutes,
the
thermal protector automatically resets
and cleaning may continue.
If the thermal protector continues to acti-
vate after following the above steps,
your cleaner may need servicing (see
“Service” section).
Service
To obtain approved HOOVER service
and genuine HOOVER parts, locate
the nearest
Hoover Factory Service
Center or Authorized Hoover
Warranty Service Dealer (Depot)
by:
• checking the Yellow Pages under
“Vacuum Cleaners - Household” OR -
•checking the list of Factory Service
Centers provided with this cleaner
OR -
•checking the Service section of The
Hoover Company on-line at
www.hoover.com
OR -
•calling 1-800-944-9200 for an
automated referral of authorized
service outlet locations (U.S. only).
Do not
send your cleaner to The Hoover
Company in North Canton for service,
this will only result in delay.
If further assistance is needed, contact
The Hoover Company Consumer
Response Center, North Canton,
Ohio 44720, Phone:
330-499-9499.
In Canada,
contact Hoover Canada,
Burlington, Ontario L7R 4A8,
Phone:
1-800-263-6376.
Always identify your cleaner by the
com-
plete
model number when
requesting information or ordering parts.
(The model number appears
on the bottom of the cleaner.)
Continued
Hoover Cleaning
Performance
This Hoover Cleaning Performance
System is for comparing the relative pro-
gressive performance of
Hoover
uprights only
and not for comparison
with any other brands. The majority of
this rating is based upon the American
Society for Testing and Materials (ASTM)
Carpet Cleaning Effectiveness Test
(ASTM Test F608). Other performance
factors include Hose Power (ASTM Test
F558), Surface Litter Cleaning, Hard
Floor Cleaning, Edge Cleaning, Cleaning
Width and Air Filtration.