IBM 6400-I15 Operation Guide - Page 100

Setup Guide.

Page 100 highlights

status and fault messages 032 FORMS JAMMED TIMEOUT CLEAR JAM AND RELOAD FORMS A timeout message is sent to the host if no paper motion has occurred for 10 minutes after Stop was pressed to clear the jam fault. Clear paper jam and reload paper. See page 72 for procedure. 034 RIBBON STALL TIMEOUT CHECK RIBBON 037 STACKER JAM TIMEOUT CHECK STACKER 038 STACKER FULL TIMEOUT CHECK STACKER 039 STACKER FAULT TIMEOUT CHECK STACKER 041 BUFFER OVERFLOW Occurs 5 seconds after the ribbon stall message if the error is not cleared. Occurs 5 seconds after the stacker jam message if the error is not cleared. Occurs 5 seconds after the stacker full message if the error is not cleared. Occurs 5 seconds after the stacker fault message if the error is not cleared. Host sends data after the printer buffer is full. (Serial interface) Check printer serial port configuration setup. Ensure that it matches host settings. 042 CUSTOM SET DOES NOT EXIST SAVE FIRST 043 CUSTOM SET ALREADY EXISTS DELETE FIRST This custom set does not exist. Define and save it. (Refer to the Setup Guide.) Custom set is write-protected. Delete existing set, then save new set. (Refer to the Setup Guide.) 044 EC FIRMWARE/HARDWARE ERROR Fatal firmware error on the controller board. Contact an IBM service representative. 86 Operator's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

status and fault messages
86
Operator’
s Guide
A timeout message is sent to the host if
no paper motion has occurred for 10
minutes after
Stop
was pressed to clear
the jam fault. Clear paper jam and reload
paper. See page 72 for procedure.
Occurs 5 seconds after the ribbon stall
message if the error is not cleared.
Occurs 5 seconds after the stacker jam
message if the error is not cleared.
Occurs 5 seconds after the stacker full
message if the error is not cleared.
Occurs 5 seconds after the stacker fault
message if the error is not cleared.
Host sends data after the printer buffer is
full. (Serial interface) Check printer serial
port configuration setup. Ensure that it
matches host settings.
This custom set does not exist. Define
and save it. (Refer to the
Setup Guide.)
Custom set is write-protected. Delete
existing set, then save new set. (Refer to
the
Setup Guide.)
Fatal firmware error on the controller
board. Contact an IBM service
representative.
032
FORMS JAMMED TIMEOUT
CLEAR JAM AND RELOAD FORMS
034 RIBBON STALL TIMEOUT
CHECK RIBBON
037 ST
ACKER JAM TIMEOUT
CHECK ST
ACKER
038 ST
ACKER FULL TIMEOUT
CHECK ST
ACKER
039 ST
ACKER F
AUL
T TIMEOUT
CHECK ST
ACKER
041 BUFFER OVERFLOW
042 CUST
OM SET DOES NOT EXIST
SA
VE FIRST
043 CUST
OM SET ALREADY EXISTS
DELETE FIRST
044 EC FIRMW
ARE/HARDWARE ERROR