IBM 6400-I15 Operation Guide - Page 103
hammer bank power cable shorted
View all IBM 6400-I15 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
088 CONTROLLER 23.5V 089 RIBBON STALL CHECK RIBBON 090 SHUTTLE COVER OPEN CLOSE SHUTTLE COVER 092 RIBBON DRIVER CIRCUIT 101 UPPER DRIVER SHORT 102 LOWER DRIVER SHORT 107 HAMMER COIL HOT 110 STACK OVERFLOW SEE USER'S GUIDE status and fault messages Controller voltage failure. Contact an IBM service representative. No ribbon movement. Make sure the ribbon is not twisted and the forms thickness lever is set to match thickness of media being used. If fault reoccurs, contact an IBM service representative. Shuttle cover is missing, damaged, or not correctly installed. Contact an IBM service representative. Controller board does not detect ribbon drive motor. Contact an IBM service representative. Hammer driver circuits on the controller board shorted to ground. Contact an IBM service representative. Circuit(s) on the hammer bank or in the hammer bank power cable shorted to ground. Contact an IBM service representative. One or more hammer coils are overheating. Stop printing and allow the printer to cool for five minutes. If the fault reoccurs, contact an IBM service representative. Fatal firmware error on the controller board. Contact an IBM service representative. Operator's Guide 89