IBM 6500-V05 Maintenance Manual - Page 220
Selecting And Running CE Tests, Press, Displayed Result, Notes, MENU + SCROLL, CONFIG + SCROLL, ENTER
View all IBM 6500-V05 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 220 highlights
Selecting And Running CE Tests To run CE Tests you use the printer configuration menus, as shown below: Selecting And Running Tests Step 1. 2. 3. 4. 5. 6. 7. 8. Press Displayed Result Load paper and power on the printer. STOP NOT READY MENU + SCROLL↑ + CONFIG + SCROLL↓ ENTER SCROLL↑ until RETURN + ENTER ENTER SERVICE PRINTER MECHANISM TESTS PRINTER MECHANISM TESTS Burn In Test PRINTER MECHANISM TESTS Plot Test OPERATOR MENU UNLOCKED Plot Test Running STOP or START NOT READY Notes Printer must be in NOT READY mode to access the tests. Press all four keys at the same time. Press ENTER to view the different mechanism tests. Cycles through list of tests. Stop when your test displays. Unlocking ENTER key allows you to test the printer. The test you selected starts printing. See Chapter 6 for instructions in the use of the Hammer Phasing and End of Forms Adjust tests. STOP halts the test, exits the menu, and puts the printer in the NOT READY state. START halts the test, exits the menu, and puts the printer in the READY state. 220