Light, diagnostics, panel
UPC - 000435813008
View all IBM 8874 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
v A new error occurs, causing the system-error LED to be lit again. Light path diagnostics panel The following table lists the LEDs on the light path diagnostics panel, the problems that they indicate, and actions to solve the problems. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Lit light path diagnostics LED with the system-error LED also lit Description Action All LEDs off (the power LED is lit). No action necessary. OVERSPEC There is insufficient power to power the system. The NON RED and LOG LEDs might also be lit. 1. Add an optional power supply if only one power supply is installed. 2. Use 220 V ac instead of 110 V ac. 3. Reseat the following components: a. Power supply b. (Trained service technician only) Power backplane 4. Remove optional devices. 5. Replace the components listed in step 3 one at a time, in the order shown, restarting the server each time. PS A power supply has failed or has 1. Reinstall the removed power supply. been removed. Note: In a redundant power configuration, the dc power LED on 2. Check the individual power-supply LEDs to find the failing power supply. one power supply might be off. 3. Reseat the following components: a. Failing power supply b. (Trained service technician only) Power backplane 4. Replace the components listed in step 3 one at a time, in the order shown, restarting the server each time. 5. If a 12 V fault has occurred, ac power must be removed before dc power can be restored. LINK There is a fault in an SMP 1. Check the SMP Expansion Port link LEDs to find Expansion Port or SMP Expansion the failing port or cable. cable. Note: The SMP Expansion Port link 2. Reseat the SMP Expansion cables. LED on the failed port is off. 3. Replace the SMP Expansion cables. 4. (Trained service technician only) Replace the scalability cartridge assembly. If the scalability cartridge assembly must be replaced, call for service. Chapter 6. Solving problems 77