IBM VXA-2 User Guide - Page 36

Reporting An Error, Backup Software Is - cleaning tape

Page 36 highlights

Problem BACKUP SOFTWARE IS REPORTING AN ERROR Solution One of the following situations may have occurred: v The drive needs cleaning. Always try cleaning the drive before you assume the cartridge is bad. Be sure to use a VXA tape cleaning cartridge. For more information, see "Using cleaning cartridges" on page 3-4. v The cartridge is incompatible with the tape drive. Be sure to use a VXA tape cartridge. v If you are trying to write data, the cartridge may be write-protected. Check the switch on the edge of the cartridge. If the switch does not cover the opening, the tape is write-protected. If the switch covers the opening, you can write to the tape. Use a pen or small screwdriver to move the switch. (See "Setting write protection on the tape cartridge" on page 3-5.) v The cartridge is not inserted properly in the drive. Remove the cartridge, then reinsert it and retry the operation. C-4 VXA-2 Internal Tape Drive: User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Problem
Solution
BACKUP SOFTWARE IS
REPORTING AN ERROR
One of the following situations may have occurred:
v
The drive needs cleaning. Always try cleaning the
drive before you assume the cartridge is bad. Be
sure to use a VXA tape cleaning cartridge. For more
information, see “Using cleaning cartridges” on
page 3-4.
v
The cartridge is incompatible with the tape drive.
Be sure to use a VXA tape cartridge.
v
If you are trying to write data, the cartridge may be
write-protected. Check the switch on the edge of the
cartridge. If the switch does not cover the opening,
the tape is write-protected. If the switch covers the
opening, you can write to the tape. Use a pen or
small screwdriver to move the switch. (See “Setting
write protection on the tape cartridge” on page 3-5.)
v
The cartridge is not inserted properly in the drive.
Remove the cartridge, then reinsert it and retry the
operation.
C-4