Dome Abnormal Phenomenon Operation

Page 27 highlights

 PASSWORD: Enable this function here so that you set password is valid. This function is on by default after you set password.  SETTING: Click the confirm button to go to the password setup interface. Please use the left/right button to set the value and then click the confirm button to confirm current option. Move the cursor to the SAVE button and then click the confirm button to save current setup. Click the BACK button to go to the previous menu.  BACK: Go back to the previous menu.  EXIT: Log out the system menu. If you have forgot your password. After three times of login failure, system may pop up an 8-digit internal code. Please contact our technical engineer for help. 3.4.5 Alarm Setting ALARM NO ACTION PARAMETER CONTACT RELAY OUT RESET DELAY SAVE BACK :1 :NONE :NONE :N/O :OFF :3S EXIT Figure 3-32 Alarm setting Move the cursor to highlight ALARM SETTING button and then click confirm button.  ALARM NO: Here is to set alarm input. Alarm input value ranges from 1 to 2. Please use the left/right button on the keyboard or in the speed dome terminal menu to set.  ACTION: Action on alarm function. It includes NONE/PRESET/AUTO SCAN/TOUR functions. Please use the left/right button on the keyboard or in the speed dome terminal menu to set.  PARAMETER: it is to set corresponding alarm operation such as scan/preset/tour. Please use the left/right button to set.  CONTACT:You can set system activation operation once alarm occurred. There are two alarm signal mode: normal open (N/O) and normal closed (N/C). Please use the left/right button on the keyboard or in the speed dome terminal menu to set.  RELAY OUT: Here is to set relay alarm mode and reset time. There are several options: off/1→5S.  1→5S:1 means the first relay output.5S means the relay will reset automatically in five seconds after alarm occurs.  RESET DELAY: Here is for you to set alarm reset time. Please use the left/right button on the keyboard or in the speed dome terminal menu to set: 3 seconds/10 seconds/30 seconds/60 seconds /120seconds. The dome will go back to previous setup after alarm acknowledgement.  SAVE:Move the cursor to SAVE and then click confirm button to save current setup.  BACK: Go back to previous menu.  EXIT: Log out system menu. 3.5 Dome Abnormal Phenomenon Operation 3.5.1 Restore to Factory Default Setup From main menu-> SYSTEM INFORMATION, move cursor to FACTORY DEFAULT and click confirm button. Dome will reboot and all the setups restore to factory default setup. 3.5.2 PTZ Movement is not smooth 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

20
ALARM NO
1
ACTION
NONE
PARAMETER
NONE
CONTACT
N/O
RELAY OUT
OFF
RESET DELAY
3S
SAVE
BACK
EXIT
PASSWORD: Enable this function here so that you set password is valid. This function is on by
default after you set password.
SETTING: Click the confirm button to go to the password setup interface. Please use the left/right
button to set the value and then click the confirm button to confirm current option. Move the cursor
to the SAVE button and then click the confirm button to save current setup. Click the BACK button
to go to the previous menu.
BACK: Go back to the previous menu.
EXIT: Log out the system menu.
If you have forgot your password. After three times of login failure, system may pop up an 8-digit
internal code. Please contact our technical engineer for help.
3.4.5
Alarm Setting
Figure 3-32 Alarm setting
Move the cursor to highlight ALARM SETTING button and then click confirm button.
ALARM NO: Here is to set alarm input. Alarm input value ranges from 1 to 2. Please use the
left/right button on the keyboard or in the speed dome terminal menu to set.
ACTION: Action on alarm function. It includes NONE/PRESET/AUTO SCAN/TOUR functions.
Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
PARAMETER: it is to set corresponding alarm operation such as scan/preset/tour. Please use the
left/right button to set.
CONTACT
You can set system activation operation once alarm occurred. There are two alarm
signal mode: normal open (N/O) and normal closed (N/C). Please use the left/right button on the
keyboard or in the speed dome terminal menu to set.
RELAY OUT: Here is to set relay alarm mode and reset time. There are several options:
off/1→5S
.
1→5S
1 means the first relay output.5S means the relay will reset automatically in five
seconds after alarm occurs.
RESET DELAY: Here is for you to set alarm reset time. Please use the left/right button on the
keyboard or in the speed dome terminal menu to set: 3 seconds/10 seconds/30 seconds/60
seconds /120seconds. The dome will go back to previous setup after alarm acknowledgement.
SAVE
Move the cursor to SAVE and then click confirm button to save current setup.
BACK: Go back to previous menu.
EXIT: Log out system menu.
3.5 Dome Abnormal Phenomenon Operation
3.5.1 Restore to Factory Default Setup
From main menu-> SYSTEM INFORMATION, move cursor to FACTORY DEFAULT and click confirm
button. Dome will reboot and all the setups restore to factory default setup.
3.5.2 PTZ Movement is not smooth