Baud Rate and Parity Setup

Page 12 highlights

Figure 2-3 There are two dial switch buttons on the PTZ. You can use them to set speed dome address, baud rate, and parity respectively. It is 1 when you set the button as ON. For the protocol dial switch, you can refer to the following sheet. 1 is the lowest bit and the 8 is the highest bit. Please note the intelligent speed dome can automatically recognize the industrial standard protocol, PELCO-D. PELCO-P. Usually you do not need to set the protocol. 2.4.2 Baud Rate and Parity Setup For the dial switch button 1-4. 1 and 2 is to set baud rate. 3 and 4 is to set parity. Please refer to the following figure for detailed information. See Figure 2-4. Figure 2-4 Please refer to the baud rate sheet for detailed information. 1 2 Baud Rate OFF OFF 9600bps ON OFF 4800bps OFF ON 2400bps ON ON 1200bps Please refer to the parity setup sheet for detailed information. 3 4 Parity OFF OFF NONE ON OFF EVEN OFF ON ODD 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

4
Figure 2-3
There are two dial switch buttons on the PTZ. You can use them to set speed dome address,
baud rate, and parity respectively. It is 1 when you set the button as ON.
For the protocol dial switch, you can refer to the following sheet.
1 is the lowest bit and the 8 is
the highest bit.
Please note the intelligent speed dome can automatically recognize the industrial
standard protocol, PELCO-D. PELCO-P. Usually you do not need to set the protocol.
2.4.2 Baud Rate and Parity Setup
For the dial switch button 1-4. 1 and 2 is to set baud rate. 3 and 4 is to set parity. Please refer to
the following figure for detailed information. See Figure 2-4.
Figure 2-4
Please refer to the baud rate sheet for detailed information.
1
2
Baud Rate
OFF
OFF
9600bps
ON
OFF
4800bps
OFF
ON
2400bps
ON
ON
1200bps
Please refer to the parity setup sheet for detailed information.
3
4
Parity
OFF
OFF
NONE
ON
OFF
EVEN
OFF
ON
ODD