IC Realtime ICIP-P2012T Product Manual - Page 26

RS485 Bus FAQ

Page 26 highlights

Figure 7-2 7.4 RS485 Bus FAQ Phenomenon Speed dome can run selfdiagnosis but I can not control it. I can control the speed dome but is not smooth Possible Reasons z Host address(baud rate) and speed dome address(baud rate) are not match; z Positive and negative end of RS485 Bus are misconnected; z Connection cable is loose; z RS485 Bus connection are cut off; z RS485 Bus connection are not good; z One RS485 bus is off; z The distance between host and speed dome is too far; z Parallel connected too much speed domes. Solution z Modify host or speed dome setup ; z Switch RS485 positive end and negative end; z Fix connection cable firmly; z Replace RS485 Bus. z Connect RS 485 Bus again; z Replace RS485 Bus; z Add terminal matching resistance; z Add RS485 distributor. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

18
Figure 7-2
7.4
RS485 Bus FAQ
Phenomenon
Possible Reasons
Solution
Speed dome
can run self-
diagnosis but I
can not control
it.
Host address(baud rate) and
speed dome address(baud rate)
are not match;
Positive and negative end of
RS485 Bus are misconnected;
Connection cable is loose
RS485 Bus connection are cut
off;
Modify host or speed dome setup
Switch RS485 positive end and
negative end
Fix connection cable firmly
Replace RS485 Bus.
I can control
the speed
dome but is not
smooth
RS485 Bus connection are not
good
One RS485 bus is off
The distance between host and
speed dome is too far
Parallel connected too much
speed domes.
Connect RS 485 Bus again
Replace RS485 Bus
Add terminal matching resistance
Add RS485 distributor.