10 SET MODE ■ ACC set mode (Continued) SEND Relay Type Selects the switching relay type for [RELAY] from Lead and MOSFET. Select the suitable relay type when connecting a non-Icom linear amplifier. Lead • Lead : Use mechanical relay. (16 V DC/0.5 A max.; default) • MOS-FET : Use semiconductor type relay. (250 V/200 mA max.) External Meter Output Selects the desired item for an external meter indication. Auto • Auto : Outputs the receiving signal strength level during receive, and outputs the selected level (selected with [METER]), during transmit. (default) • S : Outputs the receiving signal strength level during receive. • Po : Outputs the transmitting power level dur- ing transmit. • SWR : Outputs the VSWR level during transmit. • ALC : Outputs the ALC level during transmit. • COMP : Outputs the compression level during transmit. • Vd : Outputs the drain terminal voltage of the final amplifier MOSFETs. • Id : Outputs the drain current of the final amplifier MOSFETs. External Meter Level Sets the output level for an external meter indication with in 0% to 100% range in 1% steps. • Approx. 2.5 V at 50% (default) setting for full-scale indication. (4.7 kø impedance) 50% REF Adjust Adjusts the internal reference signal frequency within 0% to 100% range in 1% steps during frequency calibration. NOTE: Default setting is different for each transceiver. 50 % (Example) 125