Icom IC-M200 Instruction Manual

Icom IC-M200 Manual

Icom IC-M200 manual content summary:

  • Icom IC-M200 | Instruction Manual - Page 1
    INSTRUCTION MANUAL VHF MARINE TRANSCEIVER iM200
  • Icom IC-M200 | Instruction Manual - Page 2
    provide you with years of trouble-free operation. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL - This instruction manual contains important oper­ating instructions for the IC-M200. EXPLICIT DEFINITIONS WORD RDANGER! RWARNING
  • Icom IC-M200 | Instruction Manual - Page 3
    transceiver, as they will damage the transceiver's surfaces. If the transceiver becomes dusty or dirty, wipe it clean with a soft, dry cloth. 8. TROUBLESHOOTING 17 9. CHANNEL LIST 18 10. SPECIFICATIONS AND OPTIONS 19 DO NOT disassemble or modify the transceiver for any reason. INDEX 20 BE
  • Icom IC-M200 | Instruction Manual - Page 4
    you, cannot lawfully be used for any reason. ••Indecent or profane language is prohibited. DDRADIO LICENSES (1) SHIP STATION LICENSE You may require a current radio station license before using the transceiver. It is unlawful to operate a ship station which is not licensed, but required to be. If
  • Icom IC-M200 | Instruction Manual - Page 5
    ■■Front panel Speaker q Function display (p. 3) w uytr e q CHANNEL UP/DOWN KEYS U/I/C] zzSelects the operating channels, Set mode settings and so on. (p. 4, 12) zzSelects one of 3 channel groups in sequence when both keys are pushed. (p. 5) w POWER/VOLUME CONTROL [VOL] Rotate to turn the
  • Icom IC-M200 | Instruction Manual - Page 6
    2 PANEL DESCRIPTION ■ Function display w er t y u i q o q CHANNEL GROUP ICON Displayed when a U.S.A. "U," International " ," or Canadian "C" channel group is selected. w CHANNEL NUMBER READOUT Displays the selected channel number. L See CHANNEL LIST (p. 18) for details. e TRANSMIT ICON Displayed
  • Icom IC-M200 | Instruction Manual - Page 7
    3 BASIC OPERATION ■■Selecting a channel 1 DDChannel 16 DDCall channel 2 Channel 16 is a Distress and safety channel. It is used Each regular channel group has a separate Call 3 to make an initial contact with a station or to make channel (Default: Channel 9*). A Call channel is a 4
  • Icom IC-M200 | Instruction Manual - Page 8
    3 BASIC OPERATION ■■ Selecting a channel (continued) DDUSA,Canadian, and international channels The IC-M200 has 67 USA, 67 international, and 71 Canadian preset channels. L These channel groups may be specified for your operating area. Ask your delaer for details. 1. 
  • Icom IC-M200 | Instruction Manual - Page 9
    BASIC OPERATION 3 ■■Receiving and transmitting 1 CAUTION: Transmitting without an antenna will damage the transceiver. 2 TIP: To maximize the readability of your transmitted signal at a receiver station, pause a second after 3 pushing [PTT], and then hold the microphone 5 to 4 1. Rotate [
  • Icom IC-M200 | Instruction Manual - Page 10
    3 BASIC OPERATION ■■Setting a Call channel ■■Entering a channel name The Call channel is used to select Channel 9 (default). However, you can set another channel as the Call channel in each channel group. 1. Push [Ù] and [Ú] on the transceiver at the same time to select the desired channel group
  • Icom IC-M200 | Instruction Manual - Page 11
    BASIC OPERATION 3 ■■The Microphone Lock function ■■The AquaQuake function 1 The Microphone Lock function locks and You can use the AquaQuake function to clear water 2 [HI/LO] on the supplied microphone. The function away from the speaker grill. The function helps drain 3 prevents from
  • Icom IC-M200 | Instruction Manual - Page 12
    4 SCAN OPERATION ■■Scan types You can find ongoing calls by scanning the channels. NOTE: Before starting a scan ••Set the channels you want to scan as TAG channels. (p. 10) (Only TAG channels are scanned.) ••Select the scan type from "Normal (default)" or "Priority." (p. 13) NORMAL SCAN CH 01
  • Icom IC-M200 | Instruction Manual - Page 13
    the scanning direction or resume the scan 13 TIP: Clearing (or setting) all TAG channels While holding down [HI/LO] on the microphone, push manually. L A beep sounds and " " blinks when a signal is 14 [SCAN] for 3 seconds (until a long beep changes received on Channel 16 during Priority scan
  • Icom IC-M200 | Instruction Manual - Page 14
    5 DUALWATCH/TRI-WATCH Dualwatch and Tri-watch are convenient to monitor Channel 16 while you are operating on another channel. DUALWATCH/TRI-WATCH SIMULATION Call channel NOTE: Select Dualwatch or Tri-watch in the Set mode. (p. 13) 1. Select the desired channel. 2. Push [DW] to start Dualwatch or
  • Icom IC-M200 | Instruction Manual - Page 15
    6 SET MODE ■■Set mode 1 In the Set mode, you can change the settings of the transceiver's functions. DDSet mode sequence 2 3 NOTE: Available functions may differ depending on the dealer setting. Ask your dealer for details. • Scan type • Scan resume timer 4 5 6 DDSet mode operation 1.
  • Icom IC-M200 | Instruction Manual - Page 16
    6 BASIC OPERATION ■■Set mode items Push[▲] or [▼]to change the setting DDScan type Select whether to start the Normal scan or Priority scan after pushing [SCAN]. (p. 10) Normal scan (default) Priority scan DDScan resume timer When the function is ON, the scan pauses for 5 seconds and resumes
  • Icom IC-M200 | Instruction Manual - Page 17
    with a vulcanizing tape, as 7 shown below, to prevent water seeping into the connector. 8 Rubber vulcanizing 9 tape 10 11 12 13 e ANTENNA CONNECTOR Connects to a marine VHF antenna. 14 15 CAUTION: Transmitting without an antenna may 16 damage the transceiver. 14
  • Icom IC-M200 | Instruction Manual - Page 18
    the best place to mount them. 15 ■■Replacing a fuse If a fuse blows, or the transceiver stops functioning, find and repair the cause of the problem. Then replace the damaged fuse with a new, adequately rated fuse. Fuse Rating: 10 A ■■Cleaning If the transceiver becomes dusty or dirty, wipe it clean
  • Icom IC-M200 | Instruction Manual - Page 19
    7 CONNECTIONS AND MAINTENANCE ■ Mounting the transceiver The universal mounting bracket supplied with your transceiver enables dashboard or overhead mounting. • Mount the transceiver firmly with the 2 supplied screws (5×20 mm) on only a flat hard board that the screws won't penetrate. • Mount the
  • Icom IC-M200 | Instruction Manual - Page 20
    8 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE Power does not come on when turning ON the transceiver. Power cable is improperly connected. No sound is heard from the Volume level
  • Icom IC-M200 | Instruction Manual - Page 21
    9 CHANNEL LIST Channel number Frequency (MHz) USA INT CAN Transmit Receive 01 01 156.050 160.650 01A 156.050 156.050 02 02 156.100 160.700 03 03 156.150 160.750 03A 156.150 156.150 04 156.200 160.800 04A 156.200 156.200 05 156.250 160.850 05A 05A 156.250 156.250 06 06 06 156.300 156
  • Icom IC-M200 | Instruction Manual - Page 22
    (16K0G3E) ••Antenna impedance : 50 Ω nominal ••Operating temperature range: -20°C to +60°C ••Power supply voltage (negative ground Icom optional equipment is designed for optimal performance when used with an Icom transceiver. Icom is not responsible for the destruction or damage to the Icom
  • Icom IC-M200 | Instruction Manual - Page 23
    level 6 Output power 6 Tri-watch 11, 13 Backlight 8 Receiving 6 Troubleshooting 17 5 Call channel 4 Scan 6 Setting 7 Channel Normal scan 9 Supplied accessories 15 High power 6 Icom, Icom Inc. and Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the
  • Icom IC-M200 | Instruction Manual - Page 24
    A-7299H-1EX-q Printed in Japan © 2016 Icom Inc. 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
  • Icom IC-M200 | Instruction Manual - Page 25
    MB-69 TEMPLATE 153 (6 1 32) 139 (5 15»32) 53 (2 3 32) 67 (2 5 8) Unit: mm (inch)
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

INSTRUCTION MANUAL
iM200
VHF MARINE TRANSCEIVER