Icom IC-R20 Instruction Manual - Page 49

Scan edges programming

Page 49 highlights

SCAN OPERATION 7 ■ Scan edges programming Scan edges can be programmed in the same manner as memory channels. Scan edges are programmed into scan edges, 00A/00B to 24A/24B, in memory channels. q Push [VFO MHz] to select VFO mode. w Set the desired frequency: ➥ Select the desired band with [BAND]. ➥ Set the desired frequency with [R-DIAL]. ➥ Set other data (e.g. offset frequency, duplex direction, tone squelch, etc.), if desired. ePush [MR S.MW] for 1 sec. to select select memory write condition. • 1 short and 1 long beeps sound. • "µ " indicator blinks. rRotate [R-DIAL] to select the desired programmed scan edge channel from 00A to 24A. t Push [MR S.MW] for 1 sec. • 3 beeps sound • The other scan edge channel "B," 00B to 24B, automatically selected when continuing to push [MR S.MW] after programming. yTo program a frequency for the other pair of scan edges, 00B to 24B, repeat steps w and r. • If the same frequency is programmed into a pair of scan edges, programmed scan will not function. 7 [R-DIAL] MR S.MW [EXAMPLE]: Programming 145.300 MHz into scan edges 03A. Push MR S.MW for 1 sec. Rotate Push MR S.MW for 1 sec. -DUP TSQL AFC MODE FM ANL 145 300 PSKIP √ µ 001 FM 146..010µ -BANK-:----BNAME: -MNAME: -SKIP-:OFF >CLEAR 001 FM . µ 03A -BANK-:---- -BNAME: -MNAME: -SKIP-:OFF >CLEAR -DUP TSQL AFC MODE FM ANL 145 300 PSKIP √ µ 03A -DUP TSQL AFC MODE FM ANL 145 300 PSKIP √ µ 020 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

36
7
SCAN OPERATION
Scan edges programming
Scan edges can be programmed in the same manner as
memory channels. Scan edges are programmed into scan
edges, 00A/00B to 24A/24B, in memory channels.
q
Push
[VFO MHz]
to select VFO mode.
w
Set the desired frequency:
Select the desired band with
[BAND]
.
Set the desired frequency with
[R-DIAL]
.
Set other data
(e.g. offset frequency, duplex direction, tone
squelch, etc.)
, if desired.
e
Push
[MR S.MW]
for 1 sec. to select select memory write
condition.
• 1 short and 1 long beeps sound.
•“
µ
” indicator blinks.
r
Rotate
[R-DIAL]
to select the desired programmed scan
edge channel from 00A to 24A.
t
Push
[MR S.MW]
for 1 sec.
• 3 beeps sound
• The other scan edge channel “B,” 00B to 24B, automatically se-
lected when continuing to push
[MR S.MW]
after programming.
y
To program a frequency for the other pair of scan edges,
00B to 24B, repeat steps
w
and
r
.
• If the same frequency is programmed into a pair of scan edges,
programmed scan will not function.
[R-DIAL]
MR
S.MW
[EXAMPLE]:
Programming 145.300 MHz into scan edges 03A.
µ
MODE
ANL
AFC
TSQL
TSQL
FM
FM
145300
PSKIP
-DUP
-DUP
001
µ
MODE
ANL
AFC
TSQL
TSQL
FM
145300
PSKIP
-DUP
-DUP
03A
µ
MODE
ANL
AFC
TSQL
TSQL
FM
145300
PSKIP
-DUP
-DUP
020
>
CLEAR
CLEAR
-
SKIP
SKIP
-
:OFF
:OFF
-
MNAME:
MNAME:
-BNAME:
-BNAME:
-
BANK
BANK
-
:----
:----
001
001
µ
.
146
.
010
FM
>
CLEAR
CLEAR
-
SKIP
SKIP
-
:OFF
:OFF
-
MNAME:
MNAME:
-BNAME:
-BNAME:
-
BANK
BANK
-
:----
:----
03A
03A
µ
.
----------------
----------------
Push
for 1 sec.
Rotate
MR
S.MW
Push
for 1 sec.
MR
S.MW
7