Insignia NS-TDRE67W1 User guide - Page 26
Step 4: Connect the gas line for gas models only, Important
View all Insignia NS-TDRE67W1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
INSTALLATION INSTRUCTIONS 2 Connect one end of the exhaust ducting to the venting hole on the back of your dryer, then use aluminum tape to secure the ducting to your dryer. The crimped ends of the duct sections must point away from your dryer. Use a 4 in. (10.2 cm) diameter rigid metal duct. Exhaust ducting Back venting hole 3 Connect the other end of the ducting to the exhaust hood, then tighten the duct strap to secure it in place. Tape all joints, including at the dryer. Exhaust hood Step 4: Connect the gas line (for gas models only) Important: Before you connect the gas line, review the gas line requirements in Gas requirements on page 19. 1 Remove the pipe thread protective cap from the gas inlet. Inlet pipe on back of dryer 26 www.insigniaproducts.com