Intel ISP4400 Quick Start Guide - Page 21
Attach EIA Rail Brackets to the Rack, A
View all Intel ISP4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Attach EIA Rail Brackets to the Rack 1. Separate the brackets labeled FR/RL from the brackets labeled FL/RR. 2. Decide what side of the rack is the "front" side of the rack. 3. Place one of the brackets labeled FR/RL on the front right side of the rack as shown in Figure 12. 4. Make sure that the holes in the bracket are aligned with the holes in the rack, and that there is at least 4 inches of clearance below the bottom of the bracket. The two screws are noted by "A" in Figure 12. A OM09991 Figure 12. FR/RL Bracket Attached to Right Side of Rack 5. Secure the bracket to the rack with two screws as shown in Figure 12. 6. Place the other bracket labeled FL/RR on the front left side of the rack. 7. Align the holes in the bracket with the holes in the rack. Make sure that the top of the bracket is level with the other front right bracket already attached to the rack. The two screws are noted by "A" in Figure 13. A OM09994 Figure 13. FL/RR Bracket Attached to Right Side of Rack 8. Secure the bracket to the rack with two screws as shown in Figure 13. SRKA4 /ISP4400 Server System 21