Intel S3210SHLX Product Specification

Intel S3210SHLX - Entry Server Board Motherboard Manual

Intel S3210SHLX manual content summary:

  • Intel S3210SHLX | Product Specification - Page 1
    Intel® Server Boards S3200SH/S3210SH Technical Product Specification Intel Order Number: E14960-004 Revision 1.3 April 2008 Enterprise Platforms and Services Division
  • Intel S3210SHLX | Product Specification - Page 2
    Revision History Intel® Server Boards S3200SH/S3210SH TPS Revision History Date Sept. 2007 Oct. 2007 Jan. 2008 Apr. 2008 Revision Number 1.0 1.1 1.2 1.3 Modifications Initial release. Added new updates. Corrected some document errors. Added Intel® Embedded Server RAID Technology. ii Revision
  • Intel S3210SHLX | Product Specification - Page 3
    that you have the latest datasheet before finalizing a design. The Intel Server boards Snow Hill family may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. This document and
  • Intel S3210SHLX | Product Specification - Page 4
    Table of Contents Intel® Server Boards S3200SH/S3210SH TPS Table of Contents 1. Introduction ...1 1.1 Chapter Outline...1 1.2 Server Board Use Disclaimer 1 2. Server Board Overview ...2 2.1 Server Board Feature Set 2 2.2 Server Board Layout 10 2.2.1 Server Board Mechanical Drawings
  • Intel S3210SHLX | Product Specification - Page 5
    Intel® Server Boards S3200SH/S3210SH TPS Table of Contents 4.2 Logo / Diagnostic Window 44 4.3 BIOS Setup Utility 44 4.3.1 Operation ...44 4.3.2 Server Platform Setup Screens 47 4.4 Loading BIOS Defaults 74 4.5 Multiple Boot Blocks 74 4.6 Recovery Mode...74 4.7 Intel® Matrix
  • Intel S3210SHLX | Product Specification - Page 6
    Table of Contents Intel® Server Boards S3200SH/S3210SH TPS 6.6 Fan Headers ...91 6.7 Miscellaneous Headers and Connectors 91 94 8. Design and Environmental Specifications 95 8.1 Power Budget ...95 8.2 Power Supply Specifications 96 8.2.1 Power Timing Requirements 96 8.2.2 Dynamic
  • Intel S3210SHLX | Product Specification - Page 7
    Intel® Server Boards S3200SH/S3210SH TPS Table of Contents 9.1 Chassis Intrusion 110 Glossary...111 Reference Documents ...114 Revision 1.3 vii
  • Intel S3210SHLX | Product Specification - Page 8
    Intel® Server Boards S3200SH/S3210SH TPS List of Figures Figure 1. Intel® Server Board S3210SHLX Diagram 7 Figure 2. Intel® Server Board S3210SHLC Diagram 8 Figure 3. Intel® Server Board S3200SH-L/S3200SH-V SKU Diagram 9 Figure 4. Intel® Server Board S3210SHLC 10 Figure 5. Intel® Server Board
  • Intel S3210SHLX | Product Specification - Page 9
    33. Intel® Server Board S3210SH-LC / S3200SH-L Back Panel I/O Connectors 91 Figure 34. Intel® Server Board S3200SH-V Back Panel I/O Connectors 92 Figure 35. Output Voltage Timing 97 Figure 36. Turn On/Off Timing (Power Supply Signals 98 Figure 37. Intel® Server Board S3200SH Mechanical Drawing
  • Intel S3210SHLX | Product Specification - Page 10
    List of Tables Intel® Server Boards S3200SH/S3210SH TPS List of Tables Table 1. Intel® Server Board S3210SHLX Board SKU Layout Reference 7 Table 2. Intel® Server Board S3210SHLC Layout Reference 8 Table 3. Processor Support Matrix 17 Table 4. Segment F Connections 19 Table 5. Supported DDR2
  • Intel S3210SHLX | Product Specification - Page 11
    Intel® Server Boards S3200SH/S3210SH TPS List of 84 Table 47. POST Error Beep Codes 84 Table 48. Power Connector Pin-out (J4G1 85 Table 49. Auxiliary CPU Power Connector Pin-out (J9B2 85 Table Power Budget ...95 Table 67. Server Board Power Supply Voltage Specification 96 Revision 1.3 xi
  • Intel S3210SHLX | Product Specification - Page 12
    List of Tables Intel® Server Boards S3200SH/S3210SH TPS Table 68. Output Voltage Timing 96 Table 69. Turn On/Off Timing ...98 Table 70. Transient Load Requirements 99 Table 71. AC Line
  • Intel S3210SHLX | Product Specification - Page 13
    Intel® Server Boards S3200SH/S3210SH TPS List of Tables < This page intentionally left blank. > Revision 1.3 xiii
  • Intel S3210SHLX | Product Specification - Page 14
  • Intel S3210SHLX | Product Specification - Page 15
    and Environmental Specifications ƒ Chapter 10 - Hardware Monitoring ƒ Appendix A - Integration and Usage Tips ƒ Glossary ƒ Reference Documents 1.2 Server Board Use Disclaimer Intel Corporation server boards support add-in peripherals and contain a number of high-density VLSI and power delivery
  • Intel S3210SHLX | Product Specification - Page 16
    Server Board Overview Intel® Server Boards S3200SH/S3210SH TPS 2. Server Board Overview The Intel® Server Boards S3210SHLX, S3200SHL, S3200SHV, and S3200SHLC are monolithic printed circuit boards with features that are designed to support the entry server market. 2.1 • • • Server Board
  • Intel S3210SHLX | Product Specification - Page 17
    Intel® Server Boards S3200SH/S3210SH TPS Server Board Overview • Winbond* PC8374L super I/O chip interfaced to the ICH9R through LPC, supports the following: − PS/2 keyboard/mouse − FDD − Six SATA II connectors • Five USB 2.0 ports: two ports on USB/LAN combo connectors at the rear of the server
  • Intel S3210SHLX | Product Specification - Page 18
    Server Board Overview Intel® Server Boards S3200SH/S3210SH TPS • Video • ServerEngines* Integrated BMC • External 32MB (or greater) DDR2 533MHz memory • VGA Video external connector • Peripheral Interface (PCIe* and PCI) − Two different PCIe* configurations on single board, dependent on board SKU
  • Intel S3210SHLX | Product Specification - Page 19
    Intel® Server Boards S3200SH/S3210SH TPS Server Board Overview • System Management − Processor on die temperature monitoring through PECI interface − Board temperature measurement − Fan speed monitoring and control − Voltage monitoring − IPMI-based server management • Battery − Socketed, Lithium
  • Intel S3210SHLX | Product Specification - Page 20
    Server Board Overview Intel® Server Boards S3200SH/S3210SH TPS − One 4-pin SATA RAID Key − One 2-pin intrusion detection • BIOS − EFI BIOS • Power Management − Support for Power Management of all capable components − ACPI compliant motherboard and BIOS − Sleep Switch and dual mode LED indicator •
  • Intel S3210SHLX | Product Specification - Page 21
    Intel® Server Boards S3200SH/S3210SH TPS Server Board Overview Figure 1. Intel® Server Board S3210SHLX Diagram Table 1. Intel® Server Board S3210SHLX Board Fan 3 Connector O Battery P Main Power Connector Q System Fan 2 Connector R BIOS Jumper FF NIC1 NVM Protect Mode Jumper GG Serial
  • Intel S3210SHLX | Product Specification - Page 22
    Server Board Overview Intel® Server Boards S3200SH/S3210SH TPS The following figure shows the board layout of the LC board Figure 2. Intel® Server Board S3210SHLC Diagram Table 2. Intel® Server Board S3210SHLC Layout Reference Main Power BIOS Jumper GG NIC1 NVM Protect Mode Jumper HH Serial Port
  • Intel S3210SHLX | Product Specification - Page 23
    K AF002310 Figure 3. Intel® Server Board S3200SH-L/S3200SH-V SKU Diagram Table3. Intel® Server Boards S3200SH-L/S3200SH-V Component Layout Reference Fan3 Connector O Battery P Main Power Connector Q System Fan2 R Floppy Clear Jumper EE BIOS Jumper FF NIC1 NVM Protect Mode Jumper GG Serial
  • Intel S3210SHLX | Product Specification - Page 24
    Server Board Overview 2.2 Server Board Layout Intel® Server Boards S3200SH/S3210SH TPS Figure 4. Intel® Server Board S3210SHLC 10 Revision 1.3
  • Intel S3210SHLX | Product Specification - Page 25
    Intel® Server Boards S3200SH/S3210SH TPS 2.2.1 Server Board Mechanical Drawings Server Board Overview Figure 5. Intel® Server Board S3210SHLX - Hole and Component Positions Revision 1.3 11
  • Intel S3210SHLX | Product Specification - Page 26
    Server Board Overview Intel® Server Boards S3200SH/S3210SH TPS Figure 6. Intel® Server Boards S3210SHLC/S3200SHL/S3200SHV - Hole and Component Positions 12 Revision 1.3
  • Intel S3210SHLX | Product Specification - Page 27
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture 3. Functional Architecture This chapter provides a high-level description of the functionality associated with the architectural blocks that make up the Intel® Server Boards S3200SH/S3210SH. Revision 1.3 13
  • Intel S3210SHLX | Product Specification - Page 28
    Intel® Server Boards S3200SH/S3210SH TPS S3200SH/S3210SH LC/L/V SKU BLOCK DIAGRAM 1U Riser at Slot 6 ITP/XDP PECI Intel® SPI RJ45 Tabor PCI 33MHz RJ45 Ninevah PHY GLCI/LCI ICH9R Floppy SIO Keyboard Mouse LPC SPI BIOS Flash USB 2.0 USB 2.0 USB 2.0 I. USB R. USB R. USB USB 2.0 USB
  • Intel S3210SHLX | Product Specification - Page 29
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture S3200SH/S3210SH SYSTEM LX SKU BLOCK DIAGRAM PCI-E x8 (Slot 5) PCI-E x16 (Slot 6) DMI Controller Link 1U Riser at Slot 6 ITP/XDP PECI Intel SATA x2 Floppy SIO Keyboard Mouse LPC SPI BIOS Flash USB 2.0 USB 2.0 USB 2.0 I. USB
  • Intel S3210SHLX | Product Specification - Page 30
    Architecture Intel® Server Boards S3200SH/S3210SH TPS 3.1 Processor Sub-System The server board supports the following processors: • Dual-Core Intel® Xeon® processor 3000 series • Dual-Core Intel® Xeon® processor 3100 series • Quad-Core Intel® Xeon® processor 3200 series • Quad-Core Intel® Xeon
  • Intel S3210SHLX | Product Specification - Page 31
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture Process Name Dual-Core Intel® Xeon® processor 3000 series Quad -Core Intel® Xeon® processor 3200 series Dual-Core Intel® Xeon® processor 3100 series Dual-Core Intel® Xeon® processor 3300 series Table 3. Processor Support Matrix
  • Intel S3210SHLX | Product Specification - Page 32
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS − Interface to ICH9R South Bridge − 100 MHz reference clock shared with PCIe* interface(s) • PCIe* x8 Interface − Connected to two PCIe* X8 connectors as shown in the block diagram − Compliant with the PCIe* base specification The
  • Intel S3210SHLX | Product Specification - Page 33
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture 3.2.1.1 Segment F PCIe* x8 The MCH PCIe* Lanes 0~7 provide a x8 PCIe* connection directly to the MCH. This resource can support that must be followed when populating memory. The server board supports two DDR2 DIMM slots for channel
  • Intel S3210SHLX | Product Specification - Page 34
    Intel® Server Boards S3200SH/S3210SH TPS Please note the following memory population rules: • If dual channel operation is desired, channel A and channel B must be populated identically (i.e., same capacity) • Use DDR2 667/800 memory up to 133MHz operation and supports full-length PCI and PCI-X*
  • Intel S3210SHLX | Product Specification - Page 35
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture Table 6. Segment E Configuration IDs IDSEL Value 18 17 Device PCI-X* Slot 1 (64bit/66-133MHz) (LX board SKU only) PCI-X* Slot 2 (64bit/66-133MHz) (LX board SKU only) 3.2.2.1.2 Segment E Arbitration PXH-V supports two PCI masters:
  • Intel S3210SHLX | Product Specification - Page 36
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS provides two modes of operation - a legacy mode using I/O space and an AHCI (Advanced Host Controller Interface) mode using memory space. 3.2.3.5 PCI Interface The ICH9 PCI interface provides a 33MHz, 3.3V, Revision 2.3
  • Intel S3210SHLX | Product Specification - Page 37
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture 3.2.3.9 Real Time Clock (RTC) The ICH9 contains a Motorola* MS146818A functionally compatible Real Time Clock with two 128 Byte banks of battery backed RAM. The RTC performs two key functions on the server board: • Keeping track
  • Intel S3210SHLX | Product Specification - Page 38
    Intel® Server Boards S3200SH/S3210SH TPS two SPI flash components using two separate chip select pins. Each component may be up to 16 MB and operate in SPI Fast Read Instructions The server board will support the boot BIOS Destination Selection as defined in table below. Table 8 Boot BIOS
  • Intel S3210SHLX | Product Specification - Page 39
    , 2.7 to 3.6 volt serial interface FLASH memory, Intel part number D64145-001/D64145-002. The AT26DF321 supports the block erase command opcodes 20H and D8H providing respectively 4-Kbytes or 64-Kbytes block erase sizes. This is installed directly onto the server board without the use of sockets
  • Intel S3210SHLX | Product Specification - Page 40
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS The management engine includes a TCO Timer used to detect system locks, Process Present Indicator used to determine that the processor fetches the first instruction after reset, ECC Error reporting from the host controller, Function
  • Intel S3210SHLX | Product Specification - Page 41
    One of the embedded functions of the Intel® ICH9R is a power management controller. This is used to implement ACPI-compliant power management features. The server board supports sleep states S1, S4, and S5. 3.3 Memory Sub-System The server board supports up to four DIMM slots for a maximum
  • Intel S3210SHLX | Product Specification - Page 42
    Intel® Server Boards S3200SH/S3210SH TPS The system is designed to populate any rank on either channel, including either degenerate single channel case. DIMM and memory : 512 MB, 1 GB and 2 GB DIMMs • Serial PD: JEDEC Rev 2.0 • Voltage options: 1.8 V • Interface: SSTL2 Table 10. Memory Bank Labels
  • Intel S3210SHLX | Product Specification - Page 43
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture Figure 7. Memory Bank Label Definition Table 11. Characteristics of Dual/Single Channel Configuration with or without Dynamic Mode Throughput Level Highest Configuration Dual channel with dynamic paging
  • Intel S3210SHLX | Product Specification - Page 44
    Architecture Intel® Server Boards S3200SH/S3210SH TPS 3.3.2 Memory DIMM Support The board supports un-buffered (not registered) DDR2 667/800 ECC or non-ECC DIMMs operating at 667/800 MT/s. Only DIMMs tested and qualified by Intel or a designated memory test vendor are supported on this board
  • Intel S3210SHLX | Product Specification - Page 45
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture • One Intel® 82541PI Fast Ethernet Controller • Two slots capable of supporting full length PCI add-in cards operating at 33 MHz 3.4.1.1.1 Device IDs (IDSEL) Each device under the PCI hub bridge has its IDSEL signal connected
  • Intel S3210SHLX | Product Specification - Page 46
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS 3.4.1.2 PCI Interface for Video subsystem The server board graphics subsystem is connected to the Intel® ICH9R via a PCIe* x1 bus. 3.4.2 Interrupt Routing The board interrupt architecture accommodates both PC-compatible PIC mode
  • Intel S3210SHLX | Product Specification - Page 47
    . Floaty processor. Compatibility IDE interrupt from primary channel IDE devices 0 and 1. Secondary IDE Cable System Management Interrupt. General purpose indicator sourced by the Intel® ICH9R to the processor. 3.4.2.4 Serialized IRQ Support The server board supports a serialized interrupt
  • Intel S3210SHLX | Product Specification - Page 48
    IRQ7 IRQ8 IRQ9 IRQ10 IRQ11 IRQ12 IRQ13 IRQ14 IRQ15 IRQ16 IRQ17 IRQ18 IRQ19 IRQ20 IRQ21 IRQ22 IRQ23 ICH9R Intel® Server Boards S3200SH/S3210SH TPS ICH9R IOAPIC 0 DMI INTERFACE ICH9R 8259PIC x8 Connector x8 PCIe* interface MCH INTR CPU Figure 8. Interrupt Routing Diagram 34 Revision 1.3
  • Intel S3210SHLX | Product Specification - Page 49
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture ICH9R Interrupt Routing PCI Interface Serialized IRQ Interface Timer Super I/O Keyboard Cascade Serial Port2/ISA Serial Port1/ISA ISA Floppy/ISA
  • Intel S3210SHLX | Product Specification - Page 50
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS PCI-X* slot 6 INTD# PCI-X slot 6 INTA# PCI-X slot 6 INTC# PCI-X slot 6 INTB# PCI-X slot 5 INTD# PCI-X slot 5 INTA# PCI-X slot 5 INTB# PCI-X slot 5
  • Intel S3210SHLX | Product Specification - Page 51
    , compatible with the 16C550 • Serial IRQ Support • SMI/SCI/PME Support • ACPI Compliant • Up to 16 Shared GPIO ports • Programmable Wake-up Event Support • Plug and Play Register Set • Power Supply Control • Watchdog timer compliant with Microsoft* SHDG • LPC to SPI bridge for system BIOS support
  • Intel S3210SHLX | Product Specification - Page 52
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS • Unique Chip ID for each part, burned at the Matrix Graphics Core • 2D Hardware Graphics Acceleration • DDR-2 memory interface supports up to 128Mbytes of memory • Supports all display resolutions up to 1600 x 1200 16bpp @ 75Hz
  • Intel S3210SHLX | Product Specification - Page 53
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture The Intel 6702PXH 64-bit PCI Hub further support the new PCI Standard Hot-Plug Controller and Subsystem Specification, Revision 1.0. Each PCI interface contains an I/OxAPIC with 24 interrupts and a standard hot plug controller. 3.7
  • Intel S3210SHLX | Product Specification - Page 54
    will not be supported. 3.11 On Board Components 3.11.1 Video Support The server board includes an integrated VGA graphics engine in Integrated BMC that supports standard VGA drivers with analog display capabilities. The graphics subsystem has 8 MB memory to support the onboard video controller
  • Intel S3210SHLX | Product Specification - Page 55
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture 3.11.1.1 Video Modes 2D Mode 640x480 800x600 1024x768 1280x1024 1280x1024 1600x1200 1600x1200 Table 17. Video Modes Refresh Rate (Hz) 60, 72,
  • Intel S3210SHLX | Product Specification - Page 56
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS 3.12 Replacing the Back-Up Battery The lithium battery on the server board powers the RTC for up to ten years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in
  • Intel S3210SHLX | Product Specification - Page 57
    = Four-digit year HH = Two-digit hour using 24 hour clock MM = Two-digit minute For example, Intel® Server Board S3200SH BIOS Build 3, generated on Jan 21, 2006 at 11:59 AM has the following BIOS ID string that will be displayed in the POST diagnostic screen: S3200.86B.01.00.0003.012120061159 The
  • Intel S3210SHLX | Product Specification - Page 58
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.2 Logo / Diagnostic Window The logo / diagnostic window may be in one of two forms. In quiet boot mode, a logo splash screen is displayed. In verbose mode, a system summary and diagnostic screen are
  • Intel S3210SHLX | Product Specification - Page 59
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Functional Area Title Bar Setup Item List Item Specific Help Area Keyboard Command Bar Status Bar Table 18. BIOS Setup Page Layout Description The title bar is located at the top of the screen and displays the title of the form (page) the user
  • Intel S3210SHLX | Product Specification - Page 60
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS The Keyboard Command Bar supports is pressed in any major menu, the exit confirmation window is displayed and the user is asked whether changes next value in a menu item's option list, or a value field's pick list. The selected item must then be
  • Intel S3210SHLX | Product Specification - Page 61
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS 4.3.1.4 Menu Selection Bar The Menu Selection Bar is located at the top of the screen. It displays the major menu selections available to the user. 4.3.2 Server Platform Setup Screens The sections below describe the screens available for
  • Intel S3210SHLX | Product Specification - Page 62
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Main Advance d Security Server Management Boot Options Boot Manager Logged in as Platform ID BIOS Version Build Date Processor Intel® Xeon® CPU Core Frequency Memory Size Quiet
  • Intel S3210SHLX | Product Specification - Page 63
    BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Logged in as Platform ID System BIOS Version Build Date Processor Core Frequency Count Memory memory installed in the system, in MB or GB. The term physical memory indicates the total memory to review the errors
  • Intel S3210SHLX | Product Specification - Page 64
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Setup Item System Date System Time Options [Day of week screen is chosen. Main Advance d Security Server Management Boot Options Boot Manager ► Processor Configuration ► Memory Configuration ► SATA Controller Configuration ► Serial Port
  • Intel S3210SHLX | Product Specification - Page 65
    BIOS Intel® Server Boards S3200SH/S3210SH TPS Table 21. Setup Utility - Advanced Screen Display Fields Setup Item Processor Configuration Memory can also select an option to view information about a specific processor. To access this screen from the Main screen, select Advanced | Processor. Revision
  • Intel S3210SHLX | Product Specification - Page 66
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Advanced Processor Configuration Processor Family Core Frequency which processors currently run. Information only. Maximum frequency the processor core supports. Information only. Current frequency of the processor front side bus. Information
  • Intel S3210SHLX | Product Specification - Page 67
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Enhanced Intel® SpeedStep Technology Options Enabled Disabled Core Multi-processing Enabled Disabled Intel® Virtualization Technology Enabled Disabled Execute Disable Bit Enabled Disabled Help Text Enhanced Intel SpeedStep®
  • Intel S3210SHLX | Product Specification - Page 68
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Advanced Memory Configuration Total Memory Effective Memory Current Configuration Current Memory Speed DIMM Information DIMM_A1 DIMM_A2 DIMM_B1 DIMM_B2 Memory Correction <
  • Intel S3210SHLX | Product Specification - Page 69
    BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Current Memory Speed DIMM_# Options Memory Correction ECC Non-ECC Help Text Comments Information only. Displays speed the memory is running at. Displays the state of each DIMM socket present on the board IDE / AHCI/ RAID ► SATA Port 0
  • Intel S3210SHLX | Product Specification - Page 70
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Setup Item Onboard SATA Controller Configure SATA as SATA Port 0 SATA Port 1 SATA Port 2 SATA Port 3 SATA Port 4 SATA Port 5 Table 24. Setup Utility - ATA Controller Configuration Screen Fields Options Enabled Disabled SATA RAID IDE < Not
  • Intel S3210SHLX | Product Specification - Page 71
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Advanced Serial Port Configuration Serial A Enable Address IRQ Serial B Enable Address IRQ Enabled/Disabled 3F8h / 2F8h / 3E8h / 2E8h 3 or 4 Enabled/Disabled 3F8h / 2F8h /
  • Intel S3210SHLX | Product Specification - Page 72
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Advanced USB Configuration Detected USB Devices USB Controller Legacy USB Support Enabled / Disabled Enabled / Disabled / Auto USB Mass Storage Device Configuration Device Reset timeout 10 sec / 20 sec / 30 sec
  • Intel S3210SHLX | Product Specification - Page 73
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Table 26. Setup Utility - USB Controller by the OS. PS/2 emulation for USB keyboard and USB mouse devices. [Auto] - Legacy USB support will be enabled if a USB device is attached. USB Mass storage device Start Unit command timeout. [
  • Intel S3210SHLX | Product Specification - Page 74
    Intel® Server Boards S3200SH/S3210SH TPS Advanced PCI Configuration Dual Monitor Video Onboard NIC ROM NIC 1 MAC Address NIC 2 MAC Address Enabled / Disabled Enabled / Disabled System BIOS Figure 18. Setup Utility - PCI Configuration Screen Display Setup Item Dual Monitor Video
  • Intel S3210SHLX | Product Specification - Page 75
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Main Advanced Security Server Management Boot Options Boot Manager Administrator remove the user password. Locks the power button and reset button on the system's front panel. If [Enabled] is selected, power and reset must be controlled via
  • Intel S3210SHLX | Product Specification - Page 76
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.3.2.4 Server Management Screen The Server Management screen provides fields to configure several server Enabled] selected." System action to take on AC power loss recovery. [Stay Off] - System stays off. [Last State] - System returns to
  • Intel S3210SHLX | Product Specification - Page 77
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Clear System Event Log FRB-2 Enable O/S Boot Watchdog Timer O/S Boot Watchdog Timer Policy O/S Boot Watchdog Timer Timeout Console Redirection System Information Options Enabled Disabled Enabled Disabled Enabled Disabled Power Off
  • Intel S3210SHLX | Product Specification - Page 78
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Console Redirection Console Redirection Flow Control Baud Rate Terminal Type Legacy OS Redirection Server Management Disabled / Serial A / Serial B None / RTS/CTS 9.6k / 19.2k / 38.4k / 57.6k / 115.2k PC-ANSI / VT100 / VT100+ / VT-UTF8 Disabled
  • Intel S3210SHLX | Product Specification - Page 79
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS 4.3.2.5 Server Management System Information Screen The Server Management System Information screen provides a place to see part numbers, serial numbers, and firmware revisions. To access this screen from the Main screen, select Server
  • Intel S3210SHLX | Product Specification - Page 80
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.3.2.6 Boot Options Screen The Boot Options screen displays any bootable media encountered during POST, and allows the user to configure desired boot device. To access
  • Intel S3210SHLX | Product Specification - Page 81
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Hard Disk Order CDROM Order Floppy Order Network Device Order BEV Device Order Options Help Text Set hard disk boot order
  • Intel S3210SHLX | Product Specification - Page 82
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.3.2.6.2 CDROM Order Screen The CDROM Order screen provides a way to control the CDROM devices. To access this screen from the Main screen, select Boot Options |
  • Intel S3210SHLX | Product Specification - Page 83
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Floppy Disk #1 Floppy Disk #2 Table 35. Setup Utility - Floppy Order Fields Options Available floppy disk Available floppy disk Help Text Set
  • Intel S3210SHLX | Product Specification - Page 84
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.3.2.6.5 BEV Device Order Screen The BEV Device Order screen provides a way to control the BEV bootable devices. To access this screen from the Main screen,
  • Intel S3210SHLX | Product Specification - Page 85
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS 4.3.2.7 Boot Manager Screen The Boot Manager screen displays a list of devices available to boot from, displays any errors encountered during POST. Error Manager ERROR CODE Exit SEVERITY INSTANCE Figure 30. Setup Utility - Error Manager Screen
  • Intel S3210SHLX | Product Specification - Page 86
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Setup Item Displays System Errors Table 39. Setup discard the configuration changes made on the other screens. It also provides a method to restore the server to the factory defaults or to save or restore a set of user defined default values. If
  • Intel S3210SHLX | Product Specification - Page 87
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Discard Changes Load Default Values Save as User Default Values Load User Default Values Help Text Discard changes made since the last save changes operation was performed. Load factory default values for all BIOS Setup Utility
  • Intel S3210SHLX | Product Specification - Page 88
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.4 Loading BIOS Defaults Different mechanisms exist for resetting the system configuration to the default values. When a request to reset the system configuration is detected, the BIOS loads the default system configuration values during the
  • Intel S3210SHLX | Product Specification - Page 89
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS The following steps illustrate the recovery process: 1. Power off the system, Insert recovery media. 2. Switch the recovery jumper. 3. Power on the system. 4. The BIOS POST screen will appear and display the progress, and system would
  • Intel S3210SHLX | Product Specification - Page 90
    Handling Intel® Server Boards S3200SH/S3210SH TPS 5. Error Reporting and Handling This chapter defines following error handling features: • Error Handling and Logging • Error Messages and Beep Codes 5.1 Error Handling and Logging This section defines how errors are handled by the system BIOS. In
  • Intel S3210SHLX | Product Specification - Page 91
    Intel® Server Boards S3200SH/S3210SH TPS Error Reporting and Handling PCI PERR error PCI SERR error Code For example, the BIOS programs the hardware to generate SMI on a single-bit memory error and logs the Log). Please refer to the SMBIOS Specification, version 2.4 for more detail information.
  • Intel S3210SHLX | Product Specification - Page 92
    Error Reporting and Handling Intel® Server Boards S3200SH/S3210SH TPS Offset 00h 01h 02h 03h 04h Software NMI POST Memory Resize POST Error PCI Parity Error PCI System Error CPU Failure EISA FailSafe Timer time-out Correctable memory log disabled Logging disabled for a specific Event Type -
  • Intel S3210SHLX | Product Specification - Page 93
    processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS will display the POST code on the POST code diagnostic LEDs found on the back edge of the server board. To assist in troubleshooting a system hang during the POST process
  • Intel S3210SHLX | Product Specification - Page 94
    Reporting and Handling Intel® Server Boards S3200SH/S3210SH TPS • Red bits = 1010b = Ah • Green bits = 1100b = Ch Since the red bits correspond to the upper nibble and the green bits correspond to the lower nibble, the two are concatenated to be ACh. Table 44.: POST Progress Code LED Example
  • Intel S3210SHLX | Product Specification - Page 95
    Intel® Server Boards S3200SH/S3210SH TPS Error Reporting and Handling Checkpoint memory parameters in the memory controller Optimizing memory controller settings Initializing memory, such as ECC init Testing memory keyboard Clearing keyboard input buffer Instructing keyboard controller to run Self
  • Intel S3210SHLX | Product Specification - Page 96
    Handling Intel® Server Boards S3200SH/S3210SH TPS memory found, configured, and installed correctly Reserved for initialization module use (PEIM) Entered EFI driver execution phase (DXE) Reserved for DXE core use Started connecting drivers Started dispatching a driver Completed dispatching a driver
  • Intel S3210SHLX | Product Specification - Page 97
    Intel® Server Boards S3200SH/S3210SH TPS Error Reporting and Handling Checkpoint 0xEAh Diagnostic LED Decoder G=Green, R=Red, A=Amber MSB LSB A R A OFF Flash Update Description 0xEEh A A A OFF Calling Int 19; one beep unless silent boot is enabled. 0xEFh A A A G Reserved for DXE
  • Intel S3210SHLX | Product Specification - Page 98
    Reporting and Handling Intel® Server Boards S3200SH/S3210SH TPS Table 46. POST Error Messages and Handling Error Code Error Message CMOS date / time not set Configuration cleared by jumper Configuration default loaded Password check failed PCI resource conflict Insufficient memory to shadow PCI
  • Intel S3210SHLX | Product Specification - Page 99
    Intel® Server Boards S3200SH/S3210SH TPS 6. Connectors and Jumper Blocks 6.1 Power Connectors 6.1.1 Main Power Connector The following table defines the pin-out of the main power Red Red Black Pin 1 2 3 4 Table 49. Auxiliary CPU Power Connector Pin-out (J9B2) Signal COM COM COM COM 18 AWG
  • Intel S3210SHLX | Product Specification - Page 100
    x8. This riser card is designed for populating the Intel® Server Board S3200SH-L into the Intel® Server Chassis SR1530. 6.3 SMBus Connector Pin 1 2 3 SSI 24-pin header is provided to support a system front panel. The header contains reset, NMI, power control buttons, and LED indicators. The
  • Intel S3210SHLX | Product Specification - Page 101
    Connectors and Jumper Blocks Intel® Server Boards S3200SH/S3210SH TPS 6.5 I/O Connectors 6.5.1 VGA Connector The B8 6.5.2 NIC Connectors The server board supports two NIC RJ45 connectors. The following tables detail the pin-out of the connectors. Table 53. NIC2-Intel® 82541PI (10/100/1000
  • Intel S3210SHLX | Product Specification - Page 102
    Intel® Server Boards S3200SH/S3210SH TPS Connectors and Jumper Blocks Table 54. NIC1- Intel® 82566E (10/100 MP2 MP3 MP4 MP5 MP6 MP7 MP8 6.5.3 SATA Connectors The pin-out for the four SATA connectors is listed below. Table 55. SATA Connector Pin-out (J2K1, J1K1, J1J3, J1H3, J1H2, J1H1) Pin Signal
  • Intel S3210SHLX | Product Specification - Page 103
    Connectors and Jumper Blocks Intel® Server Boards S3200SH/S3210SH TPS Signal Name GND GND Connectors One serial port is provided on the server board. A standard, external DB9 serial connector is located on the back edge of the server board to supply a serial interface. This connector is stacked
  • Intel S3210SHLX | Product Specification - Page 104
    Intel® Server Boards S3200SH/S3210SH TPS Connectors and Jumper Blocks 6.5.6 Keyboard and Mouse Connector Two PS/2 ports are provided for use by a keyboard and a mouse. The following table details
  • Intel S3210SHLX | Product Specification - Page 105
    Jumper Blocks Intel® Server Boards S3200SH/S3210SH TPS A header on the server board provides an option to support two additional ) Pin Signal Name Type Description 1 Ground Power GROUND is the power supply ground 2 Fan Power Power Fan Power 3 Fan Tach Out FAN_TACH signal is connected
  • Intel S3210SHLX | Product Specification - Page 106
    Intel® Server Boards S3200SH/S3210SH TPS Connectors and Jumper Blocks TBD Figure 34. Intel® Server Board S3200SH-V Back Panel I/O Connectors 6.7.2 Chassis Intrusion Header A 1x2 pin header (J6J2) is used in chassis that support a chassis intrusion switch. This header is monitored by the Intel®
  • Intel S3210SHLX | Product Specification - Page 107
    Connectors and Jumper Blocks Intel® Server Boards S3200SH/S3210SH TPS 6.8 Jumper Blocks This section describes the configuration jumper options on the server board. Name CMOS Clear Password Clear Recovery Mode BMC Force Update Mode BMC Boot Block Write Protection Locatio n on LC/L/V J1E3 J1E2
  • Intel S3210SHLX | Product Specification - Page 108
    processor maximum case temperature. 2. VDD is the supply voltage for the device. 7.1 Mean Time server boards as configured from the factory is shown in the table below. Product Code Intel® Server Board S3200SH-L Intel® Server Board S3200SH-V Intel® Server Board S3210SH-LX Intel® Server Board
  • Intel S3210SHLX | Product Specification - Page 109
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8. Design and Environmental Specifications 8.1 Power Budget The following table shows the power consumed on each supply line for the server board that is configured with one processor (128W max). This configuration
  • Intel S3210SHLX | Product Specification - Page 110
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications 8.2 Power Supply Specifications This section provides power supply design guidelines for the server board, including voltage and current specifications, and power supply on/off sequencing characteristics. Parameter +
  • Intel S3210SHLX | Product Specification - Page 111
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS The 5VSB output voltage rise time will be from 1.0ms to 25.0ms Vout 10% Vout V1 V2 V3 V4 Tvout_rise Tvout_on Tvout_off Figure 35. Output Voltage Timing Revision 1.3 97
  • Intel S3210SHLX | Product Specification - Page 112
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications Table 69. Turn On/Off Timing Item Tsb_on_delay T ac_on_delay Tvout_holdup Tpwok_holdup Tpson_on_delay T pson_pwok cycle PSON turn on/off cycle Figure 36. Turn On/Off Timing (Power Supply Signals) 98 Revision 1.3
  • Intel S3210SHLX | Product Specification - Page 113
    Specifications Intel® Server Boards S3200SH/ step load size should be 60% of those listed. 8.2.3 AC Line Transient Specification AC line transient conditions are defined as "sag" AC line voltage rises above nominal voltage. The power supply shall meet the requirements under the following AC line
  • Intel S3210SHLX | Product Specification - Page 114
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications Duration Continuous 0 to ½ AC cycle Table 72 trips for any of the power supply protection circuits. • The surge-withstand test must not produce damage to the power supply. • The supply must meet surge-withstand test
  • Intel S3210SHLX | Product Specification - Page 115
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.3.2 Product EMC Compliance - Class A Compliance Note: Legally the product is required to comply with Class A emission requirements as it is intended for a commercial
  • Intel S3210SHLX | Product Specification - Page 116
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications 8.3.4 RoHS Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration
  • Intel S3210SHLX | Product Specification - Page 117
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.3.5 Product Regulatory Compliance Markings This product is marked PB Free Marking Australia / New Zealand Korea Exporting Requirements Environmental Requirements CPU-S3200SH (A) MADE IN xxxxx Revision 1.3 103
  • Intel S3210SHLX | Product Specification - Page 118
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications 8.4 Electromagnetic Compatibility Notices 8.4.1 FCC (USA) This device and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
  • Intel S3210SHLX | Product Specification - Page 119
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.4.2 ICES-003 (Canada) Cet it may cause radio interference. Install and use the equipment according to the instruction manual. 8.4.5 Taiwan Declaration of Conformity (BSMI) The BSMI Certification Marking and EMC
  • Intel S3210SHLX | Product Specification - Page 120
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications 8.4.6 Korean Compliance (RRL) English translation of the notice above: Type of Equipment (Model Name): On License and Product Certification No.: On RRL certificate. Obtain certificate from local Intel representative
  • Intel S3210SHLX | Product Specification - Page 121
    Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.5 Mechanical Specifications The following figure shows the Intel® Server Board S3200SH mechanical drawing. This drawing will be updated in a future revision of this document. Figure 37. Intel® Server Board S3200SH Mechanical
  • Intel S3210SHLX | Product Specification - Page 122
    Design and Environmental Specifications The following figures show the I/O shield mechanical drawings for use in pedestal mount applications, such as the Intel® Entry Server Chassis SC5299-E, for the three board SKUs. The Intel® Server Board S3200SH-L and the Intel® Server Board S3200SH-LX/LC share
  • Intel S3210SHLX | Product Specification - Page 123
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS Figure 39. Pedestal Mount I/O Shield Mechanical Drawing for Intel® Server Boards S3200SH-L / S3210SH-LX Revision 1.3 109
  • Intel S3210SHLX | Product Specification - Page 124
    Intel® Server Boards S3200SH/S3210SH TPS Hardware Monitoring 9. Hardware Monitoring 9.1 Chassis Intrusion The server board supports a chassis security feature that detects if the chassis cover is removed. For the chassis intrusion circuit to function, the chassis' power supply must be connected
  • Intel S3210SHLX | Product Specification - Page 125
    on the server board. Data Carrier Detect Direct Memory Access Distributed Management Task Force Error Correcting Code Electromagnetic Compatibility External Product Specification Extended System Configuration Data Floppy Disk Controller First-In, First-Out Field replaceable unit 1024 MB. General
  • Intel S3210SHLX | Product Specification - Page 126
    Intel® Server Boards S3200SH/S3210SH TPS Term LSB MB MBE Ms MSB MTBF Mux NIC NMI OEM Ohm PBGA PERR PIO PMB PMC PME PnP POST PWM RAIDIOS RAM RI Power Management Event Plug and Play Power-on Self Test Pulse-Width Modulator RAID I/O Steering Random Access Memory Ring Indicate Reduced instruction
  • Intel S3210SHLX | Product Specification - Page 127
    Intel® Server Boards S3200SH/S3210SH TPS Term VGA VID VRM Word ZCR Video Graphic Adapter Voltage Identification Voltage Regulator Module 16-bit quantity Zero Channel RAID Definition Glossary Revision 1.3 113
  • Intel S3210SHLX | Product Specification - Page 128
    Reference Documents Refer to the following documents for additional information: z Intel® S3200 Server Board Family Datasheet z Intel® 3200 Series Chipset Memory Controller Hub Datasheet. z Intel® ICH9 I/O Controller Hub Datasheet. 114 Revision 1.3
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

Intel
®
Server Boards
S3200SH/S3210SH
Technical Product Specification
Intel Order Number: E14960-004
Revision 1.3
April 2008
Enterprise Platforms and Services Division